this is odd...
There should be 3 wires on a stock points powered starter. Large battery cable, yellow on the R terminal that'll go up to the coil, and a purple wire on the S terminal that goes to the ignition switch.

If the truck has been updated to HEI, then remove the yellow wire and run only the battery and purple.