View Single Post
Old 08-04-2011, 11:36 PM   #24
ItsRandy
Registered User
 
ItsRandy's Avatar
 
Join Date: Nov 2010
Location: Grand Terrace, Ca.
Posts: 1,607
Re: New 4 row Radiator, New Fan, New Water Pump and Stat - still running hot!

Quote:
Originally Posted by ubtripn View Post
I thought a thermostat either was open or closed not metering in between. Learn something new everyday.
Posted via Mobile Device
As someone else said, the thermostat temp is the minimum temp. After that it is supposed to regulate the temp so the motor runs at close to optimum (or design) temp. The valve in the thermostat is constantly moving as it tries to maintain a consistent temp after the motor warms past the design temp of the thermostat (160*, 180* etc). The radiator and water pump supply the coolant the thermostat asks for, all the parts work together, that's why it is called the "cooling system".


Sorry about the double post.
ItsRandy is offline   Reply With Quote