View Single Post
Old 12-19-2012, 10:28 PM   #12
LockDoc
The Older Generation


 
LockDoc's Avatar
 
Join Date: Aug 2006
Location: Montezuma, Iowa
Posts: 26,098
Re: Suburban runs, only with key in start position

Quote:
Originally Posted by Yerboogieman View Post
Okay, so I hooked it to the "unfused" and unhooked the yellow wire from the starter. It does the same exact thing. Completely stumped.
I don't know if you have tried this or not... Unhook the power wire from the HEI. Turn the ignition switch to the "ON" position. Using either a circuit tester or multimeter see if the wire you unplugged from the HEI is hot. If it is, I see no reason the truck shouldn't run, unless the ignition module is bad. If it isn't hot then there is either a problem with the switch or the wire between the switch and the "Ign Unfused" terminals in the fuse box.

LockDoc
__________________
Leon

Locksmith, Specializing In Antique Trucks, Automobiles, & Motorcycles

(My Dually Pickup Project Thread)

http://67-72chevytrucks.com/vboard/s...d.php?t=829820

-