moneyguru, A friend did his shop with the radiant heat, so thats where I got the idea. If you type in "radiant heat" on your search engine you will get alot if info... I used 900' of 1/2" "pex" tubing (3, 300' lengths) buried in the concrete. A typical 40 gallon hot water tank, a manifold system made from copper tubing, and a $80.00 dollar recirculating pump made for this type of application. The pump uses only 65 watts. I also insulated the foundation around the outside (2' deep)