Originally Posted by Painter D
If I leave it do I need to plug it with something or just leave it open to the elements? I'd rather remove it and plug the hole in the intake, if anybody knows a good remedy for doing this feel free to let me know.
|
The purge valve is normally closed. So, you can just remove the hose from it and leave the valve connected to the intake. You can also run a pipe tap in the hole and use a pipe plug to close it off. I can't remember off the top of my head if it's a 3/8 or 1/4 pipe tap, but its obvious because only one of those sizes will fit in the hole.