Re: Above Ground lift questions

After looking into it further I think I have found the problem. I will need to change up some things then try it again with the dually. I never really paid it any mind when I took it down at the P.O. shop. He had 12 gauge wire run to the motor so I assumed everything was good I hooked it into my exhaust fan circuit which is also 20 amp 12 gauge wire. I just got reading the plate on the motor and it is 22 amp max draw so it is a wonder the breaker has not tripped with the heavy load of the dually. I am going to run some 10 gauge wire wit ha 30 amp breaker and that should take care of the problem.
__________________
Members I have met.
Dually Jams, OlBlue60, ScottH, Tommyboy24, Dujobo, Warbucket, 2003 Silverado, Notsolo, my90k5, 6t727t2, Special-K ,Jack_71C10, tabarcus,72blazer_mud_bogger,pwdcougar,RSavage,EricSean,1Rippen6,invicta455,tennaragtop71,arks, Kendal,Bennett68C10, Perpendicular, Chainsawman, McGeesCustomMinis,ShortbedClayton,longblue72,6768chevylover,Tim71,Travisarmenta,Ol' Drippy,fleetmitch,georgieb51,Dave,bcnya2,Dadsburb