Quote:
Originally Posted by aboesec10
cool, I'm pretty darn sure thats the one I've got it plumbed into. Ill double check this evening. Maybe ill try to jump the control valve with 12 volts and see if that opens it up
|
IF you have a 2 wire control solonoid you can trigger it with 12V and ground you will hear the valve clicking.
the new plastic style 3 Wire may be a little more difficult.
honestly the best way to check if the valve is working is to feel the hoses going into and out of the valve when set to heat mode. Is there a Temperature differential? If there is then there may be an issue with the valve being stuck closed. In which case I MAY try manually over riding the valve to see if that helps.
If you do all this and are still having issues call Vintage Air. Their tech guys are great and know their products.