Looks like you can use it in boosted application.

The diagrams in the specs cover a few different models. Blocking and nonblocking, not sure which this specific model is

You don't have a return line now, but I think if I was re-plumbing anyway I'd want one. Electric pumps like having flow for cooling. The way your truck is wired it appears the electric pump only runs under boost so it may not matter much, but decide if you want want a return line and non blocking regulator or no return line and a blocking regulator