Old 03-27-2007, 08:06 AM   #1
68_Step
Registered User
 
Join Date: Feb 2003
Location: Marshfield, MO
Posts: 355
Cranking motor from under the hood

Is there an easy way to turn over a motor while under the hood? In the past I have used one of those remote starts that connect to the starter, but with this 67 C-10 that is a royal pain to attach. The starter solenoid is buried behind the frame and exhaust manifold, my hands just will not fin in there! Sure would be helpful for setting initial timing... Thanks in advance.
68_Step is offline   Reply With Quote
Old 03-27-2007, 08:25 AM   #2
Orange
Licensed to Thrill!
 
Orange's Avatar
 
Join Date: Apr 2006
Location: Northwest, GA
Posts: 1,673
Re: Cranking motor from under the hood

So I suppose it would be just as bad laying a screwdriver or something across the positive/negative of the starter solenoid? (Just as you needed to of course).
__________________
1971 GMC.Lowered. Overdrive. Orange.
Krue's excellent FAQ Index.

Last edited by Orange; 03-27-2007 at 08:25 AM.
Orange is offline   Reply With Quote
Old 03-27-2007, 03:16 PM   #3
Longhorn Man
its all about the +6 inches
 
Longhorn Man's Avatar
 
Join Date: Jan 2001
Location: Hilliard Ohio
Posts: 2,690
Re: Cranking motor from under the hood

well, if you are doing this a lot, you could run a wire from a 2 prong plug to the bat cable on the starter, and then the one from the other side of the plug to the S terminal, and then put the same style plug on your remote starter... or even mount a push button under the hood.
Longhorn Man is offline   Reply With Quote
Old 03-27-2007, 03:23 PM   #4
Chevyholic
Will it run today?
 
Chevyholic's Avatar
 
Join Date: Feb 2007
Location: DFW, Texas
Posts: 272
Re: Cranking motor from under the hood

I installed a remote solenoid on my inner fender, so its as easy as taking a screwdriver to the pos and neg there. Downside is that it is that easy for anyone to do, if you get my drift. Need to come up with a non-invasive way to secure the hood.
__________________
Jaws, the 1971 Chevy Cheyenne Longbed.
She's big, grey, and has an insatiable appetite!
Chevyholic is offline   Reply With Quote
Old 03-27-2007, 03:26 PM   #5
hvychve
To The Levy
 
hvychve's Avatar
 
Join Date: Jan 2007
Location: california
Posts: 391
Re: Cranking motor from under the hood

There is always the purple 10 ga. wire that runs to s terminal on the starter for almost every chevrolet.... chevy has been pretty consistant on this color wire, its a fat purple wire , I believe you can pull it from the loom that is on the back of the fire wall, I would not just poke a hole in it with a tee pin and hook remote starter to it and positive battery, but rather maybe cut it and make a correct splice connection for your remote starter , I have seen many guys just jam somthing into the wire to tap into it and leave the hole exposed, not a good idea, especially if you live where it snows and salt sets in, it will take no time at all for this open exposed wire to corrode and gain high resistance and eventually major voltage drop and even break the circuit.
hvychve is offline   Reply With Quote
Old 03-27-2007, 03:54 PM   #6
bryanw1968
Senior Member
 
bryanw1968's Avatar
 
Join Date: Jul 2006
Location: Leander, Texas
Posts: 850
Re: Cranking motor from under the hood

You could always just pull the plugs out and turn it pretty easily by the crank w/o stripping the bolt?
bryanw1968 is offline   Reply With Quote
Old 03-27-2007, 08:42 PM   #7
68_Step
Registered User
 
Join Date: Feb 2003
Location: Marshfield, MO
Posts: 355
Re: Cranking motor from under the hood

Quote:
Originally Posted by hvychve View Post
I believe you can pull it from the loom that is on the back of the fire wall, I would not just poke a hole in it with a tee pin and hook remote starter to it and positive battery, but rather maybe cut it and make a correct splice connection for your remote starter
Do I have this right: Connect the remote starter to the purple wire and to the positive on the battery - - the motor should turn over when the remote starter in engaged?
68_Step is offline   Reply With Quote
Old 03-28-2007, 07:44 PM   #8
hvychve
To The Levy
 
hvychve's Avatar
 
Join Date: Jan 2007
Location: california
Posts: 391
Re: Cranking motor from under the hood

yes, but considering you live in Minnisota? you might want to keep the exposed wire that you cut, (however you decide to tap into this wire) sealed or properly tapped into, so as not to allow corrossion to set in, yes the big purple (10 ga. wire should be located in the loom at rear of firewall and one lead from remote start to it and other to a positive sourse, either on the back of alternator or positive battery and than push button and it should crank, keep in mind if its a stick, it will run you over if its in gear and be careful that you are aware of fan and belts are clear of those vital human body parts before cranking with a remote button,
hvychve is offline   Reply With Quote
Old 03-28-2007, 10:25 PM   #9
RACINJASON22
GEARHEAD
 
RACINJASON22's Avatar
 
Join Date: Jan 2007
Location: CENTRAL,PA
Posts: 2,284
Re: Cranking motor from under the hood

All Correct except the fact it will not run this way. It will turn over just not start as you are looking for. you will have to make another switch 12 volt loop to the ignition/dizzy for it to actually run. RJ22
__________________
72 SWB 2WD MY PROJECT
72 LWB 4X4 FUTURE PROJECT

SUBSCRIBE HEREBOARD VENDORS HERE

NORWOOD MEET SURVIVOR!
RACINJASON22 is offline   Reply With Quote
Old 03-29-2007, 12:04 AM   #10
VetteVet
Msgt USAF Ret

 
VetteVet's Avatar
 
Join Date: Jan 2005
Location: Kalamazoo, Michigan
Posts: 8,718
Re: Cranking motor from under the hood

If he has points ignition it will start and run as long as he has the solenoid engaged. If it is an automatic he could just jump from the neutral start switch to any twelve volt source and it will crank the engine. The original post sounds like he wants to just crank the engine to set the points unless I am missing something. A little more info would be helpful.
__________________
VetteVet

metallic green 67 stepside
74 corvette convertible
1965 Harley sportster
1995 Harley wide glide

Growing old is hell, but it beats the alternative.
VetteVet is offline   Reply With Quote
Old 03-29-2007, 01:00 AM   #11
kwmech
Senior Member
 
Join Date: Mar 2003
Location: Colfax-California
Posts: 8,630
Re: Cranking motor from under the hood

This has been discussed previously from a different point of view. That discussion revolved around the started getting 'heat soaked'. The fix for that was installing a ford starter solenoid, and bringing the factory wiring over to that and jumping the chevy solenoid below.
kwmech is offline   Reply With Quote
Old 03-29-2007, 07:12 AM   #12
68_Step
Registered User
 
Join Date: Feb 2003
Location: Marshfield, MO
Posts: 355
Re: Cranking motor from under the hood

hvychve: I live in Missouri, but I would still seal the connection.
RACINJASON22: I do not need it to start, just turn over.
VetteVet: HEI distributer and I was getting the #1 to TDC before dropping the distributer in.
68_Step is offline   Reply With Quote
Old 03-29-2007, 11:28 AM   #13
Fenny
Junior Member
 
Join Date: Dec 2004
Location: Calgary AB
Posts: 41
Re: Cranking motor from under the hood

If you just need it to turn over you could always get something like this http://store.summitracing.com/partde...5&autoview=sku for $10 bucks.
__________________
72 GMC 3/4 ton Custom Camper 5.3 ltr 4l60e
72 Chevy Blazer 4x4 327 4spd
70 Olds Cutlass supreme 455 4spd m21
Fenny is offline   Reply With Quote
Old 03-29-2007, 11:37 AM   #14
RACINJASON22
GEARHEAD
 
RACINJASON22's Avatar
 
Join Date: Jan 2007
Location: CENTRAL,PA
Posts: 2,284
Re: Cranking motor from under the hood

Fenny thats what he has now. He's looking for an easier way to hook something like this product up other than by way of getting into the tight area between exh manifold and frame.
I think best choice is kill two birds with one stone and install the remote selinoid on the fenderwell or werever you chose. You will the have very convenient hook up for remote starter and cure any future issues with starter heat soak.
__________________
72 SWB 2WD MY PROJECT
72 LWB 4X4 FUTURE PROJECT

SUBSCRIBE HEREBOARD VENDORS HERE

NORWOOD MEET SURVIVOR!

Last edited by RACINJASON22; 03-29-2007 at 11:38 AM.
RACINJASON22 is offline   Reply With Quote
Old 03-29-2007, 11:43 AM   #15
Fenny
Junior Member
 
Join Date: Dec 2004
Location: Calgary AB
Posts: 41
Re: Cranking motor from under the hood

Guess I should read the whole post.
__________________
72 GMC 3/4 ton Custom Camper 5.3 ltr 4l60e
72 Chevy Blazer 4x4 327 4spd
70 Olds Cutlass supreme 455 4spd m21
Fenny is offline   Reply With Quote
Old 03-29-2007, 11:46 AM   #16
RACINJASON22
GEARHEAD
 
RACINJASON22's Avatar
 
Join Date: Jan 2007
Location: CENTRAL,PA
Posts: 2,284
Re: Cranking motor from under the hood

We all do it myself included from time to time
__________________
72 SWB 2WD MY PROJECT
72 LWB 4X4 FUTURE PROJECT

SUBSCRIBE HEREBOARD VENDORS HERE

NORWOOD MEET SURVIVOR!
RACINJASON22 is offline   Reply With Quote
Old 03-29-2007, 11:55 AM   #17
snj8198
Registered User
 
snj8198's Avatar
 
Join Date: Feb 2007
Location: Star Valley, WY
Posts: 2,038
Re: Cranking motor from under the hood

I use a remote starter solenoid. It's a hand held unit with push button switch using 5ft leads and aligator clips that clip to the starter allowing you to turn the motor from outside the cab. I use it for finding TDC or adjusting valves. Just kill the ignition 12v source. They're not cheap, about $75 but nice to have if you do this a lot.
snj8198 is offline   Reply With Quote
Old 04-02-2007, 07:45 AM   #18
68_Step
Registered User
 
Join Date: Feb 2003
Location: Marshfield, MO
Posts: 355
Re: Cranking motor from under the hood

Thanks for the help everybody. I think I am going to go the remote solenoid route or splicing into the "purple" wire.

I love this board...
68_Step is offline   Reply With Quote
Reply

Bookmarks

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -4. The time now is 06:49 AM.


Powered by vBulletin® Version 3.8.11
Copyright ©2000 - 2024, vBulletin Solutions Inc.
Copyright 1997-2022 67-72chevytrucks.com