Register or Log In To remove these advertisements. |
|
|
![]() |
|
Thread Tools | Display Modes |
![]() |
#1 |
Registered User
Join Date: Feb 2009
Location: southeasternfoothillsofusa
Posts: 1,557
|
![]()
I'm thinking of using solder lugs to convert the ends of buggered-up-ended battery cables--from 2-ga. to 6-ga.--to 'eye-loop' type and then bolt them on to ground such as block-to-frame, block-to-body, block-to-cab, frame-to-bed, etc. Are there any disadvantages to using these round wires vs. flat stranded wiring made specifically for grounding?
I realize the cost, with solder lugs, would be greater; but since I have no other use for these deteriorated-end cables, thought I'd use 'em for grounding, if there are no drawbacks. Thanks for ideas and caveats. Sam |
![]() |
![]() |
![]() |
#2 |
Registered User
Join Date: Jun 2012
Location: cleawater florida
Posts: 246
|
Re: grounding wires: flat specialty or round battery cable?
sounds like a good plan to me. I did the same thing on a car that was mostly electronic. fuel inj, gauges,fuel pump,etc. grounds are critical for everything to work right. only thing I did was to heat shrink end lugs.
|
![]() |
![]() |
![]() |
Bookmarks |
Thread Tools | |
Display Modes | |
|
|