10-18-2013, 03:19 PM | #1 |
Registered User
Join Date: Mar 2012
Location: edgartown mass
Posts: 852
|
electrical nightmare
ok guys i am really lost here. i replace the ip in my 6.2 and when i was bleeding it out i burned up the starter.(was dying anyway). replaced that was cranking again then it stoped. so replace the key switch and was good to go for about 15 seconds when it stoped again. thought i burned the link change that and was good then stoped again forgot the ground for cab to motor. change link and still nothing. is there a fuse or something? anything that i have missed?
__________________
1986 c20 "the hillbilly" 350 sm465 3.42gears 21mpg at 70mph 1985 k30 "the ice cream truck from hell" no rust az truck 197-8??? c30 "ramp truck" 454 1978 monte carlo 350 350th with 2.73 gears. no rust. sc car Last edited by old Rusty C10; 10-18-2013 at 06:24 PM. |
10-21-2013, 06:23 AM | #2 |
Registered User
Join Date: Feb 2007
Location: Memphis MI
Posts: 1,851
|
Re: electrical nightmare
Whre to start?
1. Bad battery cables - you need both batteries to crank a 6.2, I've actually melted the post out of RH battery when the joint got hotter than the lead would take, because the current flowing thru that connector. 2. When you did the starter did you put a new solenoid on? 3. Check for voltage at the starter. Then hook you meter to the solenoid wire from the key. When you turn the key you should see 12 V at the start wire - if not, switch or wire. If so, if the solenoid clicks, cables or starter fail. If no click, most lilely cables.
__________________
1987 2 ton 1982 250/TH350 beater in progress Dad's 1981 3/4 L6 3 on tree posi and no options, awaiting restoration or scrapping Plus a mess o' tractors |
Bookmarks |
Thread Tools | |
Display Modes | |
|
|