The 1947 - Present Chevrolet & GMC Truck Message Board Network







Register or Log In To remove these advertisements.

Go Back   The 1947 - Present Chevrolet & GMC Truck Message Board Network > 47 - Current classic GM Trucks > The 1967 - 1972 Chevrolet & GMC Pickups Message Board

Web 67-72chevytrucks.com


Reply
 
Thread Tools Display Modes
Old 06-06-2002, 04:43 PM   #1
69&72Bowties
Registered User
 
Join Date: Jun 2002
Location: Pineville, LA
Posts: 78
Angry Under Dash Air Questions

I have a 1972 Cheyene. When I bought it and restored it 1 year ago it came with the under dash air unit. After quizing people about this unit they said it was a dealer option.

Has anyone messed with these before? I cleaned it up and put all new hoses, evaporator, condesor, etc on it along with Charging it with 134A.

The lowest we could get the temp is 56 degrees.. That is no where near cold enough to cool down the cab.. Does anyone know if I need to switch expansion valves to a 134A valve, Or are they the same? I have been told that I need to replace that...

I would like to keep this and use it for the next couple of years... I would love to hear some thoughts from anyone on this issue..

Thanks for your help!

Bryan
69&72Bowties is offline   Reply With Quote
Old 06-06-2002, 06:00 PM   #2
Willy Prost
Senior Member
 
Join Date: Jan 2000
Location: Arlington, VA
Posts: 398
First thought is did you change the dissicant dryer when you replaced and recharged with 134?

Second thought is to ask the question on
www.aircondition.com
they have a discussion board only dealing with automotive AC.

Yeah, 134 isn't as efficient as 12, but you should be able to get the duct outlet temperature a lot colder than 56 degrees.
Willy Prost is offline   Reply With Quote
Old 06-07-2002, 09:27 AM   #3
69&72Bowties
Registered User
 
Join Date: Jun 2002
Location: Pineville, LA
Posts: 78
The only thing I didnt change with the expansion Valve and any internal components of the Under Dash Unit its self... I changed all of the outside pieces before I had the system charged.

Are there any differences between expansion valves? Is the one I have for R12 and not 134A? I am wondering if the valve is to big and not compressing the 134a enough to make it colder?


I might be out in left field on this, but it was worth a shot!

Bryan
69&72Bowties is offline   Reply With Quote
Old 06-07-2002, 09:53 AM   #4
imaindianoutlaw
GMC SHORT FLEET F/S
 
imaindianoutlaw's Avatar
 
Join Date: Jun 2000
Location: SOUTH WILLIAMSPORT PENNSYLVANNIA
Posts: 2,117
Is there a valve in there? Some systems have a cap tube to monitor the refrigerant through. Are you assumming there is a charge problem? You may want to look into a different refrigerant such as hot shot! 414b
__________________
CHARLES WADE HEIN

HVACR FOREMAN.
LEWISBURG U.S.P.
imaindianoutlaw is offline   Reply With Quote
Old 06-07-2002, 10:36 AM   #5
69&72Bowties
Registered User
 
Join Date: Jun 2002
Location: Pineville, LA
Posts: 78
Will hot shot work with a 134A compressor? Is it expensive or about the same price at 134A?

I am not familar with it....

Yes I have an expansion valve on the system... It has a temp tube that runs into the system to monitor temps.. (I guess)...

I can get a replacement valve, but I dont know of anybody that knows if there is a difference between the 2?
69&72Bowties is offline   Reply With Quote
Old 06-07-2002, 11:52 AM   #6
imaindianoutlaw
GMC SHORT FLEET F/S
 
imaindianoutlaw's Avatar
 
Join Date: Jun 2000
Location: SOUTH WILLIAMSPORT PENNSYLVANNIA
Posts: 2,117
Hot shot is about twice as much as 134a but is more efficient! You cant buy it in the 12 oz cans a far as I know but it works great! How much is the new valve? If it is a replacement valve it should be the same thing? I have never replaced a valve for 134a! I dont know if your valve is adjustable, but thats what I have to do some times! Superheat adjustments on the valve are made to monitor it through the coil. I would have to assujme your valve would be ok with 134a, but I am not working on the system and seeing whats going on?
__________________
CHARLES WADE HEIN

HVACR FOREMAN.
LEWISBURG U.S.P.
imaindianoutlaw is offline   Reply With Quote
Old 06-07-2002, 01:47 PM   #7
69&72Bowties
Registered User
 
Join Date: Jun 2002
Location: Pineville, LA
Posts: 78
Okay I have taken my system apart and out of the truck... I have the ex valve in front of me. The part number is 31616 and says R-12-45 on it...


So I am guessing wrong vavle?
69&72Bowties is offline   Reply With Quote
Old 06-07-2002, 08:29 PM   #8
69&72Bowties
Registered User
 
Join Date: Jun 2002
Location: Pineville, LA
Posts: 78
I went and picked up a replacement EX valve, but it dont state whether it is for R12 or R134a? It is adjustable, Do I need to adjust it before I install it?

Please help?
69&72Bowties is offline   Reply With Quote
Reply

Bookmarks

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -4. The time now is 12:23 AM.


Powered by vBulletin® Version 3.8.11
Copyright ©2000 - 2024, vBulletin Solutions Inc.
Copyright 1997-2022 67-72chevytrucks.com