The 1947 - Present Chevrolet & GMC Truck Message Board Network







Register or Log In To remove these advertisements.

Go Back   The 1947 - Present Chevrolet & GMC Truck Message Board Network > 47 - Current classic GM Trucks > The 1967 - 1972 Chevrolet & GMC Pickups Message Board

Web 67-72chevytrucks.com


Reply
 
Thread Tools Display Modes
Old 08-11-2006, 10:17 PM   #1
incoma
Registered User
 
incoma's Avatar
 
Join Date: Mar 2004
Location: Lexington, KY
Posts: 865
blower motor wiring question

I've been having sporatic problems with my blower motor not working. With everything in the truck off, and the key in the "on" position, I can hear a light click when I turn on the blower fan, but I don't always turn on the blower. I'm thinking the heater resistor may be failing, but how can I be sure? I don't want to swap that and it turn out that the blower motor isn't working..!!

If the blower were bad, would it sometimes work and other times not work?
__________________
"Green Monster" (Red Sox fan)
1970 GMC survivor, 350/200 4R, 3.42 rear gears, 2.5/4 drop, ECE disc brake conversion, powder coated suspension
incoma is offline   Reply With Quote
Old 08-12-2006, 07:27 AM   #2
70GMCer
Senior Member
 
70GMCer's Avatar
 
Join Date: Apr 2005
Location: Joppa, Maryland
Posts: 4,408
Re: blower motor wiring question

You need a volt meter to see if you are getting 12 volts to the motor when it is heater control switch is on. Test it at the firewall where you unplug the wire that is on the motor. Turn the fan switch on and then take 1 meter test lead to that wire and the other lead to a negative ground. If the meter shows 12 volt, it is good. Do this to all the speeds on the heater control. If no voltage, work your way back to the heater control testing for voltages.
__________________
1997 GMC Sierra Ext

1965 Mustang
70GMCer is offline   Reply With Quote
Old 08-12-2006, 01:42 PM   #3
centsless
sufficiently talented fool
 
centsless's Avatar
 
Join Date: Jun 2006
Location: Forest Hill, MD
Posts: 2,231
Re: blower motor wiring question

Do exactly what 70gmcer said, then check the ground. With the fan on, touch the volt meter leads to the negative battery post and to the ground on the blower motor. By doing this you are checking voltage drop. It should be minimal. If it reads anything over about one half of a volt, you have a ground problem. You can do this on any circuit. The volt meter measures the difference between the two leads. The voltage at one end of the wire should be the same at the other, that is why the reading should be as close to zero as possible. Hope that helps !
__________________
"it's impossible to be surrounded by idiots when you are part of the circle"
2003 Suburban
2002 Pontiac Montana
1981 Corvette
1966 Impala Convertible
Click here to support the board
centsless is offline   Reply With Quote
Old 08-12-2006, 04:32 PM   #4
incoma
Registered User
 
incoma's Avatar
 
Join Date: Mar 2004
Location: Lexington, KY
Posts: 865
Re: blower motor wiring question

ok guys, thanks for the help. I played with it yesterday - not using a meter, just disconnecting and reconnecting things and it started working. Not 100% yet, but 75% of the time. I'm going to find some electrical grease and see if that doesn't fix the 25% of the time. If it doesn't I'll hit the volt meter. I'm not the best with wiring troubleshooting and try to avoid it at all costs!
__________________
"Green Monster" (Red Sox fan)
1970 GMC survivor, 350/200 4R, 3.42 rear gears, 2.5/4 drop, ECE disc brake conversion, powder coated suspension
incoma is offline   Reply With Quote
Old 08-12-2006, 11:43 PM   #5
jhow66
Registered User
 
jhow66's Avatar
 
Join Date: Jun 2002
Location: Knoxville Tenn.
Posts: 3,058
Re: blower motor wiring question

The click you hear is the blower relay on the pass. side up by the right side of glove box. If you can move the relay it means that the ground wire is not making contact all the time.The wire (black) hooks to one of the screws that mount the relay to the heater and AC box.To check it just run you a jumper from the relay to a good ground. If it works all the time then you have found your problem. (the above advice carries no implied warrenty)
__________________
56 Chevy Bel-Air 2dr. HT (purchased new)
71 Chevy Cheyenne SWB PU (502HO)
65 GMC short bed step--work in progress and my gofer
jhow66 is offline   Reply With Quote
Reply

Bookmarks


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -4. The time now is 11:51 PM.


Powered by vBulletin® Version 3.8.11
Copyright ©2000 - 2024, vBulletin Solutions Inc.
Copyright 1997-2022 67-72chevytrucks.com