fan motor speed issue

Wondering if anyone else has ran across this issue. I'm trying to get my AC/heater to work. Initially, I was getting power to the motor, but the motor wasn't coming on. The motor worked fine when off and tested on a battery. I put it back on and cleaned/tightened all the grounds and it now works. That was probably just a grounding issue.
Now my current problem. When I turn the switch on low and medium speed works fine however, when I put it in high it goes back to low or off. Anybody have any ideas? I thought it might be the relay or resistor, but I thought I would ask you guys first. Thanks in advance. M
hogrocket is offline   Reply With Quote
Old 01-28-2007, 10:53 PM   #2
hogrocket
Junior Member
 
Join Date: Apr 2006
Location: San Diego
Posts: 100
Re: fan motor speed issue

New question--I was reading some older threads on this subject and found some mentioning a high speed relay. I know where the one is near the glove box, but where is the "high speed" one located? Could that be my problem. By the way this is a 70 K20 AC truck. Thanks, M
hogrocket is offline   Reply With Quote
Old 01-28-2007, 10:57 PM   #3
Longhorn Man
its all about the +6 inches
 
Longhorn Man's Avatar
 
Join Date: Jan 2001
Location: Hilliard Ohio
Posts: 2,690
Re: fan motor speed issue

that one under the glove box is the relay you are looking for. Odds are, it is the problem.
Longhorn Man is offline   Reply With Quote
Old 01-28-2007, 11:10 PM   #4
BLACK AND BLUE 67-72
Firefighter
 
BLACK AND BLUE 67-72's Avatar
 
Join Date: Feb 2001
Location: Yellville, Ar, USA
Posts: 1,943
Lightbulb Re: fan motor speed issue

The blower motor resistor could also cause this type of problem
__________________
'72 Chevy SWB 350 Auto
'67 GMC LWB 350 4 speed
'70 Chevy 4x4 Stepside 350 Auto
Yellville, Ar. USA

BLACK AND BLUE 67-72 is offline   Reply With Quote
Old 01-29-2007, 12:32 AM   #5
FLEET72
Registered User
 
FLEET72's Avatar
 
Join Date: Jan 2007
Location: Sonoma, CA
Posts: 521
Re: fan motor speed issue

The resistor assy reduces the voltage at low and medium speed. High is the full 12V. If the motor does not run on high when in the truck you need to check the connectors @ the resistor and/or at the switch. Also it is possible that the switch is bad.

Check this thread for the wiring diagram: http://67-72chevytrucks.com/vboard/s...d.php?t=185665
__________________
Oscar
'72 Shortbed Fleetside
'95 Jimmy 4X4
'69 GMC Custom Camper

Last edited by FLEET72; 01-29-2007 at 12:32 AM.
FLEET72 is offline   Reply With Quote
Old 01-29-2007, 07:54 PM   #6
Hutch
Registered User
 
Hutch's Avatar
 
Join Date: Oct 2001
Location: Grapevine, Tx.
Posts: 2,142
Re: fan motor speed issue

hogrocket
Mine had the same issue and it was the ground from the relay.
It is behind the glove box up high on the firewall between the heater box and the passenger side wall.
It is a short wire that allot of folks do not properly attach after a heater coil replacement.
It is a very short wire and easy to get left off.
__________________
John Hutchison
Grapevine,Texas

68 1/2 t swb
68 Mustang
69 Jaguar
71 1/2 t swb
88 Supra CompTs6m
93 Escort GT
2005 Corolla XRS
Hutch is offline   Reply With Quote
Reply

Bookmarks


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -4. The time now is 09:17 PM.


Powered by vBulletin® Version 3.8.11
Copyright ©2000 - 2024, vBulletin Solutions Inc.
Copyright 1997-2022 67-72chevytrucks.com