Voltage Regulator - Is this normal?

My battery went dead, and when I hook up the jumper cables I noticed the voltage regulator clicks. It seems to me that if that's the sound of a solenoid closing, the voltage regulator would be drawing battery power all of the time.

So how do I test the voltage regulator? I haven't had to test one in many years.

If it's a bad regulator, I'll probably just install the internal regulator alternator I have in my garage.

Thanks
truckster is offline   Reply With Quote
Old 08-07-2008, 11:22 AM   #2
68gmsee
Active Member
 
68gmsee's Avatar
 
Join Date: Jul 2007
Location: Centrally located between Houston, Austin and Waco. BCS area.
Posts: 7,947
Re: Voltage Regulator - Is this normal?

It's a mechanical regulator. They have relays inside that open and close depending on the charging needs of the battery. If you supect it's bad, the new ones are fairly cheap and most are solid state. I converted mine to solid state some time back and it works fine.

http://upload.wikimedia.org/wikipedi...Stabilizer.JPG
68gmsee is offline   Reply With Quote
Old 08-07-2008, 12:24 PM   #3
gcburdic
Restoration Virgin!
 
gcburdic's Avatar
 
Join Date: Jan 2008
Location: Huntersville, NC
Posts: 8,298
Re: Voltage Regulator - Is this normal?

Quote:
Originally Posted by truckster View Post
My battery went dead, and when I hook up the jumper cables I noticed the voltage regulator clicks. It seems to me that if that's the sound of a solenoid closing, the voltage regulator would be drawing battery power all of the time.

So how do I test the voltage regulator? I haven't had to test one in many years.

If it's a bad regulator, I'll probably just install the internal regulator alternator I have in my garage.

Thanks
Hey truckster,

Use this thread from FAQ to wire up that internal regulated alt.....and trash that external one....it'll cost you nothing!!!!!!
__________________
Geoff with a G
1968 Chevy C10 SWB The Mistress

1972 Custom Deluxe C20 Suburban A Suburban Named Isabella

1966 Ford Mustang Mama's High School Graduation Present
gcburdic is offline   Reply With Quote
Old 08-07-2008, 12:27 PM   #4
Longhorn Man
its all about the +6 inches
 
Longhorn Man's Avatar
 
Join Date: Jan 2001
Location: Hilliard Ohio
Posts: 2,693
Re: Voltage Regulator - Is this normal?

it'll cost nothing after buying a new alt with an internal regulator.
Longhorn Man is offline   Reply With Quote
Old 08-07-2008, 12:33 PM   #5
chevy_mike
Never Ending Projects
 
chevy_mike's Avatar
 
Join Date: Jul 2006
Location: San Diego, CA
Posts: 3,836
Re: Voltage Regulator - Is this normal?

I was running into this as well. Found out the PO had plugged the connector into the regulator in backwards. After plugging it in the correct way, all the problems went away.

It answered the question as to why they had a "kill switch" which would kill all the power to the whole truck. This would keep it from killing the battery.

Check the connector and make sure it is correct. I had to search online to find a wiring diagram which I used to figure this out.
__________________
.
1965 C10 Panel, Tiki Express http://www.67-72chevytrucks.com/vboa...d.php?t=506580 SOLD
1968 Chevy C10, Long, Fleetside, Hot Rod Hauler http://67-72chevytrucks.com/vboard/s...d.php?t=313233 SOLD
1965 Chevy C10, Long, Fleetside, Hot Rod C10 http://67-72chevytrucks.com/vboard/s...d.php?t=415702 SOLD


We were given two ears and one mouth for a reason... listen twice as much and speak half as often...

Last edited by chevy_mike; 08-07-2008 at 12:35 PM.
chevy_mike is offline   Reply With Quote
Old 08-07-2008, 12:58 PM   #6
gcburdic
Restoration Virgin!
 
gcburdic's Avatar
 
Join Date: Jan 2008
Location: Huntersville, NC
Posts: 8,298
Re: Voltage Regulator - Is this normal?

Quote:
Originally Posted by truckster View Post
......If it's a bad regulator, I'll probably just install the internal regulator alternator I have in my garage.

Thanks
Quote:
Originally Posted by Longhorn Man View Post
it'll cost nothing after buying a new alt with an internal regulator.
Hey LHM.....must still be peeved about WSTF.....see the last sentence from his post....
__________________
Geoff with a G
1968 Chevy C10 SWB The Mistress

1972 Custom Deluxe C20 Suburban A Suburban Named Isabella

1966 Ford Mustang Mama's High School Graduation Present
gcburdic is offline   Reply With Quote
Old 08-07-2008, 02:52 PM   #7
Longhorn Man
its all about the +6 inches
 
Longhorn Man's Avatar
 
Join Date: Jan 2001
Location: Hilliard Ohio
Posts: 2,693
Re: Voltage Regulator - Is this normal?


k, I'm busted.
Longhorn Man is offline   Reply With Quote
Old 08-07-2008, 04:38 PM   #8
prg machine
Registered User
 
prg machine's Avatar
 
Join Date: Jun 2007
Location: oregon
Posts: 1,069
Re: Voltage Regulator - Is this normal?

The only difference with the external and the internal regulator alternators is where the regulator is. Except!..................the externaly regulated alternators have transistors that are beefier and cooled in the case of the alternator.

The rebuilders told me when i asked if |i should go internal one wire and they just laughed " Only if you want to be techy!" The externaly regulated is bullet proof. If ya have one just fix it. The one wire is also a misconception...............the only good thing about them is there is only one wire to hook up...............it stops there!

Read the articles on mad electric web site.
__________________
69 K-20 cloned to a 67 with front clip and some other stuff.
383 .040 over
Crane roller cam lifters and rockers ,1.6 intake ratio, Open chamber heads, 9.5-1 compression ratio, 2.02 intake valves , Edelbrock performer Air Gap manifold Carter AFB performer 750cfm, MSD ignition, SM465 NP205 4.10 gears:
prg machine is offline   Reply With Quote
Old 08-07-2008, 08:22 PM   #9
68gmsee
Active Member
 
68gmsee's Avatar
 
Join Date: Jul 2007
Location: Centrally located between Houston, Austin and Waco. BCS area.
Posts: 7,947
Re: Voltage Regulator - Is this normal?

Quote:
Originally Posted by prg machine View Post
........... The externaly regulated is bullet proof...........
I guess that's why mine lasted for 40 years. I don't think it was bad when I replaced it. I think I still have the original one somewhere though.
68gmsee is offline   Reply With Quote
Old 08-07-2008, 10:07 PM   #10
truckdude239
Senior Member
 
truckdude239's Avatar
 
Join Date: Sep 2005
Location: Lewisville, Nc
Posts: 10,237
Re: Voltage Regulator - Is this normal?

cost me 32 buxs to convert over to a internal reg External to Internal Voltage reg. i went though3 after market extrnal reg.s and an alt with no luck then switched tot the internal reg no problems since
__________________
David fuller
Ase Certified Mechanic
Click here to help support our board!!


1971 Chevy c-10 under going a 4.8l LSx swap

Build Thread http://67-72chevytrucks.com/vboard/s...d.php?t=421305

2007 Honda Accord my daily 145kmiles
2002 Honda Accord 4 door With 330k(sisters car)
2005 toyota Avalon 228k( brothers car)
2002 Sububran 5.3 245k
2000 Tahoe 5.3l 378

General manager for Marco's Carwash & lube

Last edited by truckdude239; 08-07-2008 at 10:09 PM.
truckdude239 is offline   Reply With Quote
Old 08-08-2008, 03:50 PM   #11
prg machine
Registered User
 
prg machine's Avatar
 
Join Date: Jun 2007
Location: oregon
Posts: 1,069
Re: Voltage Regulator - Is this normal?

Quote:
Originally Posted by truckdude239 View Post
cost me 32 buxs to convert over to a internal reg External to Internal Voltage reg. i went though3 after market extrnal reg.s and an alt with no luck then switched tot the internal reg no problems since
something must have been seriously wrong with the set up to go through all of those compnents.
these things were built solid.
__________________
69 K-20 cloned to a 67 with front clip and some other stuff.
383 .040 over
Crane roller cam lifters and rockers ,1.6 intake ratio, Open chamber heads, 9.5-1 compression ratio, 2.02 intake valves , Edelbrock performer Air Gap manifold Carter AFB performer 750cfm, MSD ignition, SM465 NP205 4.10 gears:
prg machine is offline   Reply With Quote
Old 08-08-2008, 04:32 PM   #12
19673ontree
CAN'T FIX NOTHIN
 
19673ontree's Avatar
 
Join Date: Sep 2006
Location: SOUTHRUST VIRGINIA !!!
Posts: 2,112
Wink Re: Voltage Regulator - Is this normal?

when I was younger I had some car's and truck's with the newer internal regulator type alternator and the HEI distributor's and those were the only thing's that EVER caused me to have to sit beside the road broke down ,
the factory 1960's early 70's alternator and regulator system should be right up there with the best creation's in the automotive world , I have NEVER had one minute's trouble out of one , and they will charge with a piece of string for a belt , the internal one's have to have the belt torqed to 500 foot pound's and then the still sqeal !!
2ND the GM point's type distributor is a mechanical marvel !! bullet proof easy to work on and CHEAP my 67 camaro has had two set's of point's in the last ten year's and that second set is still in the box in the trunk for whenever I need them ,
__________________
1967 C10 Shortbed Fleetside Small back glass
6 cyl 3spd on the tree 3.08 gears
underdash AC

Last edited by 19673ontree; 08-08-2008 at 04:37 PM.
19673ontree is offline   Reply With Quote
Old 08-08-2008, 06:05 PM   #13
LONGHAIR
just can't cover up my redneck
 
Join Date: May 2004
Location: Columbus OH
Posts: 11,414
Re: Voltage Regulator - Is this normal?

Quote:
Originally Posted by prg machine View Post

The rebuilders told me when i asked if |i should go internal one wire and they just laughed " Only if you want to be techy!" The externaly regulated is bullet proof. If ya have one just fix it. The one wire is also a misconception...............the only good thing about them is there is only one wire to hook up...............it stops there!

Read the articles on mad electric web site.
Hold on there, you threw in a different thing.
"One Wire" and "Internally Regulated" are not the same thing.
A "One Wire" is internally regulated...but it is a newer "Hot Rod" thing.

An "Internally Regulated" alternator actually runs from 3 wires. These are the "common" units that are installed from the factory. They are what they used to replace/update the older externally regulated units.
LONGHAIR is offline   Reply With Quote
Old 08-08-2008, 07:58 PM   #14
68gmsee
Active Member
 
68gmsee's Avatar
 
Join Date: Jul 2007
Location: Centrally located between Houston, Austin and Waco. BCS area.
Posts: 7,947
Re: Voltage Regulator - Is this normal?

I'm sure cost was one of the reasons Detroit went with internal regulator alternators and mechanical points. Throw in a diode assembly plus some transistors and do away with a lot of mechanical components.

Other reasons could have been the higher power demands of the newer automobiles.
68gmsee is offline   Reply With Quote
Old 08-08-2008, 09:57 PM   #15
prg machine
Registered User
 
prg machine's Avatar
 
Join Date: Jun 2007
Location: oregon
Posts: 1,069
Re: Voltage Regulator - Is this normal?

Quote:
Originally Posted by LONGHAIR View Post
Hold on there, you threw in a different thing.
"One Wire" and "Internally Regulated" are not the same thing.
A "One Wire" is internally regulated...but it is a newer "Hot Rod" thing.

An "Internally Regulated" alternator actually runs from 3 wires. These are the "common" units that are installed from the factory. They are what they used to replace/update the older externally regulated units.
No you are definitely right and I am not meaning that they are one and the same................it is just that all of the current trend is to "think" that the one wire and the internal regulated alternators are the cat's meow. They are sold by Summit and Jegs so everyone thinks they are the hot set up for their street machines...................not so!

www.madelectrical.com/electrical-tech

check out the articles on the mad electrical web site
__________________
69 K-20 cloned to a 67 with front clip and some other stuff.
383 .040 over
Crane roller cam lifters and rockers ,1.6 intake ratio, Open chamber heads, 9.5-1 compression ratio, 2.02 intake valves , Edelbrock performer Air Gap manifold Carter AFB performer 750cfm, MSD ignition, SM465 NP205 4.10 gears:
prg machine is offline   Reply With Quote
Old 08-08-2008, 11:33 PM   #16
stanglifemike
Registered User
 
stanglifemike's Avatar
 
Join Date: Jan 2008
Location: Carrollton, GA
Posts: 43
Re: Voltage Regulator - Is this normal?

I had a chrome 1 wire alt built for me at a local Auto Electric shop. Cost $130 and looks/functions great
__________________
71 C-10
98 Mustang GT
06 Mustang GT

Last edited by stanglifemike; 08-08-2008 at 11:41 PM.
stanglifemike is offline   Reply With Quote
Old 08-09-2008, 01:23 AM   #17
El Jay
Gone to greener pastures
 
Join Date: May 2007
Location: Gateway to the Delta
Posts: 7,354
Re: Voltage Regulator - Is this normal?

Quote:
Originally Posted by stanglifemike View Post
I had a chrome 1 wire alt built for me at a local Auto Electric shop. Cost $130 and looks/functions great
Not to get too far off topic.
Personally, I'd ditch that glass fuel filter before you burn your truck to the ground & ruin your whole day.

They look nice & all, but all you have to do is have it break and pump gasoline all over your hot engine, especially if you're driving.

Just my .02.
__________________
'69 Chevy 1/2 T LWB Stepper: Daily Beater
'72 GMC 3/4 T Fleet: Another Daily Beater
'72 Plymouth Gran Coupe: ?


"Ah women. They make the highs higher and the lows more frequent." Friedrich Nietzsche

"Never kick a fresh turd on a hot day." Harry S. Truman

GUN CONTROL: Never having to say, "I missed you."

Always fire two warning shots into your attacker's chest area before putting a bullet between his eyes. Paraphrased from Louis Awerbuck
El Jay is offline   Reply With Quote
Old 08-09-2008, 11:37 AM   #18
prg machine
Registered User
 
prg machine's Avatar
 
Join Date: Jun 2007
Location: oregon
Posts: 1,069
Re: Voltage Regulator - Is this normal?

If you go to Madelectrical.com and read the articles you will understand why I am trying to point out that the one wire set up is not the way to go unless it is on a tractor that doesn't have lights or accessorys or a drag car.
with the 1 wire set up the aternator only puts out a set voltage and will not "scence" that there is a voltage drop downstream at the headlights for instace, and it will not "know" to step up the voltage.
Don't take my word for it and this is not based on my general "opinion" either, just read the articles and you will undestand what i am saying.
__________________
69 K-20 cloned to a 67 with front clip and some other stuff.
383 .040 over
Crane roller cam lifters and rockers ,1.6 intake ratio, Open chamber heads, 9.5-1 compression ratio, 2.02 intake valves , Edelbrock performer Air Gap manifold Carter AFB performer 750cfm, MSD ignition, SM465 NP205 4.10 gears:
prg machine is offline   Reply With Quote
Reply

Bookmarks


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -4. The time now is 11:47 PM.


Powered by vBulletin® Version 3.8.11
Copyright ©2000 - 2024, vBulletin Solutions Inc.
Copyright 1997-2022 67-72chevytrucks.com