The 1947 - Present Chevrolet & GMC Truck Message Board Network







Register or Log In To remove these advertisements.

Go Back   The 1947 - Present Chevrolet & GMC Truck Message Board Network > 47 - Current classic GM Trucks > The 1967 - 1972 Chevrolet & GMC Pickups Message Board

Web 67-72chevytrucks.com


Reply
 
Thread Tools Display Modes
Old 07-28-2003, 02:02 PM   #1
charles oliver
68 camtruck
 
charles oliver's Avatar
 
Join Date: Mar 2000
Location: Harrison, Ohio USA
Posts: 233
Question Gas Gauge Sending Unit

I replaced Gas Gauge sending unit and it doesn't have a place for a ground, the original didn't either. It doesn't work any ideas on how to ground it.
68 Chevy C10 Short bed stepside
charles oliver is offline   Reply With Quote
Old 07-28-2003, 02:07 PM   #2
lukecp
Formerly yellow72custom
 
lukecp's Avatar
 
Join Date: May 2001
Location: Austin, TX
Posts: 7,531
The sending unit shouldn't be grounded. If it is grounded out, the guage will go way past full and not work.
__________________
'72 Chevy C10 Mild 350/TH350/3.07. Ochre/White. Old high school ride.
'70 GMC C2500 '62 327 4bbl/SM465/4.56-geared Dana 60. White/White. Project or parts truck.
'97 Saturn SL DD. 1.9/5-speed. 40+ highway mpg
lukecp is offline   Reply With Quote
Old 07-28-2003, 02:42 PM   #3
bpmcgee
Registered User
 
bpmcgee's Avatar
 
Join Date: Mar 2003
Location: Northern Illinois
Posts: 2,181
72,

I have to disagree with you. The sending unit MUST be grounded. It takes two wires to make a circuit, and there's only a brown wire coming from the guage.

Sending units are usually grounded via the tank. When I switched to a poly tank, I had to create a separate ground by running a grounding strap from one of the screws on the flange to the body.

If your tank is metal, you need to make sure that you have a good clean metal all the way from the sending unit to the frame. Alternately, you can jam a spade terminal between the sending unit and the locking ring, then run a wire from there to the frame.

Brian
bpmcgee is offline   Reply With Quote
Old 07-28-2003, 02:49 PM   #4
lukecp
Formerly yellow72custom
 
lukecp's Avatar
 
Join Date: May 2001
Location: Austin, TX
Posts: 7,531
You are right, but there isn't a ground wire to the sending unit. That is what i was refering to. It should be grounded through the tank, assuming charle oliver has a original metal thank, there is no need for a ground wire. The tank is attached in about 4 places to the frame, so unless it is really corroded, it should work.
__________________
'72 Chevy C10 Mild 350/TH350/3.07. Ochre/White. Old high school ride.
'70 GMC C2500 '62 327 4bbl/SM465/4.56-geared Dana 60. White/White. Project or parts truck.
'97 Saturn SL DD. 1.9/5-speed. 40+ highway mpg
lukecp is offline   Reply With Quote
Old 07-28-2003, 04:26 PM   #5
charles oliver
68 camtruck
 
charles oliver's Avatar
 
Join Date: Mar 2000
Location: Harrison, Ohio USA
Posts: 233
I am having a problem with understanding how the sending unit is grounded to the tank. There is a rubber O ring that separates the sending unit from the tank. I have tried 4 different gas gauges and none work. If I remove the wire to the fuse block it registers way past full. When I hook it back up it goes to empty and there is plenty of gas in it. This was also true before I replaced the tank sending unit. Any other ideas ?
Thanks
Charlie
__________________
71 GMC Jimmy 4X4
68 Huger Orange Camaro 454 with TH400 :gmc
:
charles oliver is offline   Reply With Quote
Old 07-28-2003, 06:59 PM   #6
lukecp
Formerly yellow72custom
 
lukecp's Avatar
 
Join Date: May 2001
Location: Austin, TX
Posts: 7,531
If it goes to empty after hooking the wire back up, the float on the gas tank may be full of gas, or it fell off. Pull the sending unit and see what it looks like.
__________________
'72 Chevy C10 Mild 350/TH350/3.07. Ochre/White. Old high school ride.
'70 GMC C2500 '62 327 4bbl/SM465/4.56-geared Dana 60. White/White. Project or parts truck.
'97 Saturn SL DD. 1.9/5-speed. 40+ highway mpg
lukecp is offline   Reply With Quote
Old 07-28-2003, 07:06 PM   #7
Bill72BB
Thats the Hillbilly way
 
Bill72BB's Avatar
 
Join Date: Jul 2001
Location: Torrance,Ca
Posts: 5,979
charles oliver
You said you removed the wire at the fuse block and it went past full ,
Now remove the wire at the sending unit if it goes past full again them the problem is with the sending unit or float.
If it stays on Empty the wire is grounded , replace it and that should fix the problem.
__________________
BILL
Torrance Calif 90504
Member DUF Club
Member Old Farts Club
72 3/4ton Custom Camper BB402/400 trans Dynomax Cerama-coat headers , Hei distributor ,Edelbrock 1411 air,ps,pb,leafsprings ,98 chevy 60/40 seat,S10 shoulder belts
tilt,3.54 Dana 60 rear. 16" Eagle wheels with LT265/75 16 tires,Gaylord Lid,H4 headlights with 100W relay conversion.


" If I knew I was going to live this long I would have taken better care of myself "
Marriage changes passion...suddenly you're in bed with a relative. A GUY'S PRAYER....

Lord, I pray for a nympho with huge boobs who owns a liquor store and likes to fish and hunt and has a Harley .Amen ,
Bill72BB is offline   Reply With Quote
Old 07-28-2003, 08:10 PM   #8
71GMC_3/4T
Weapons Of Construction
 
71GMC_3/4T's Avatar
 
Join Date: Apr 2000
Location: Colorado, USA
Posts: 1,095
Yep, I was going to say that too. I'll be the brown wire is pinched by the seat, trim, or gas tank.
__________________
1971 GMC 2500, 402/TH400 4.10 Daily Driver
Lafayette, CO
71GMC_3/4T is offline   Reply With Quote
Old 07-28-2003, 09:03 PM   #9
mtdave2
newly minted old timer
 
mtdave2's Avatar
 
Join Date: Dec 1999
Location: Hudson WI
Posts: 3,521
after you put the unit in the tank, you put on a metal ring to hold it in. that is what is making the ground. you have a bad spot in the wire someplace.
__________________
____________________________________________
72 c20 longhorn 65k org miles and counting!
69 k10 Suburban
mtdave2 is offline   Reply With Quote
Old 08-04-2003, 06:03 PM   #10
charles oliver
68 camtruck
 
charles oliver's Avatar
 
Join Date: Mar 2000
Location: Harrison, Ohio USA
Posts: 233
You were absolutely right. The wire was pinched where I couldn't see it.
Thanks
Charlie
charles oliver is offline   Reply With Quote
Reply

Bookmarks


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -4. The time now is 12:20 AM.


Powered by vBulletin® Version 3.8.11
Copyright ©2000 - 2024, vBulletin Solutions Inc.
Copyright 1997-2022 67-72chevytrucks.com