Blower Motor,interesting problem
This morning i started my truck to warm up before work. i go outside after 15 minutes and it doesnt feel too warm in the cab. Not a big deal because it didnt frost over the windows. I felt the defrost vents and nothing.. i start driving to work and it starts blowing out the vents just fine. ok no problem i think. I get to work and check it when i park, no air through the vents again. Now the heat works well when it works. I have replaced the radiator and heater core and all hoses, all withing past 2 years. heat worked fine this spring without an issuse. it doesnt seem to have any coolant issue, just air flow issue. what would cause this? is it a voltage issue where the blower motor doesnt get enough to engage until im driving?
|
10-22-2015, 09:46 AM | #2 | |
Registered User
Join Date: Dec 2007
Location: Santa Maria, Ca.
Posts: 1,423
|
Re: Blower Motor,interesting problem
Quote:
.
__________________
69 Chevy 4x4 383 Power |
|
10-22-2015, 09:53 AM | #3 |
Registered User
Join Date: Jan 2015
Location: Channahon IL
Posts: 50
|
Re: Blower Motor,interesting problem
Does the Amp meter work? if so what does It read? Does it start blowing if its sitting and you rev the engine a little? does it still blow when you come to a stoplight? I remember my old blower motor had a bad bearing and it would sound god awful sometimes and just fine other times. Eventually it got to the point where it would only work about 1/2 the time lol. I changed it out and had no problems. (maybe $15-$20 at auto zone but its made in china!) its kind of a pain in the ass because you have to take off the passenger hood hinge. I tied my hood to a hook in the ceiling with a rope so I wouldn't need to take it all the way off.
|
10-22-2015, 06:11 PM | #4 |
Registered User
Join Date: Sep 2015
Location: Rogersville, MO
Posts: 82
|
Re: Blower Motor,interesting problem
Could you hear the motor running? Perhaps a low vacuum at idle keeping the damper from diverting up to the windshield?
|
10-22-2015, 07:20 PM | #5 |
Registered User
Join Date: Jul 2015
Location: North East PA
Posts: 684
|
Re: Blower Motor,interesting problem
Sounds like a ground issue , but could be switch . as stated check connections , then if connections seem good add temporary ground wire to one of the blower motor through bolts rite to your negative terminal on the battery . if that works then just make up a new ground to body if not move on to the switch it self .
|