air bag compressors tripping breaker

installed rear air bags in my 1964,dual compressor ,has 60 amp circuit breaker,with truck running breaker will flip before tank is full @ 90 psi,relays seem warm to touch,any ideas to resolve this?i believe the relays are 40 amp,this was a full air ride kit,but only did rear,
rickywideglide is offline   Reply With Quote
Old 06-19-2019, 11:51 AM   #2
SCOTI
Registered User
 
SCOTI's Avatar
 
Join Date: Apr 2001
Location: DALLAS,TX
Posts: 22,064
Re: air bag compressors tripping breaker

What size wiring? What length between breaker, power source, & compressor/s?
__________________
67SWB-B.B.RetroRod
64SWB-Recycle
89CCDually-Driver/Tow Truck
99CCSWB Driver
All Fleetsides
@rattlecankustoms in IG

Building a small, high rpm engine with the perfect bore, stroke and rod ratio is very impressive.
It's like a highly skilled Morrocan sword fighter with a Damascus Steel Scimitar.....

Cubic inches is like Indiana Jones with a cheap pistol.
SCOTI is offline   Reply With Quote
Old 06-19-2019, 07:40 PM   #3
rickywideglide
Registered User
 
rickywideglide's Avatar
 
Join Date: Jun 2013
Location: mechanicsville,md
Posts: 360
Re: air bag compressors tripping breaker

I followed schematic shown,6 ga wire is about 7 feet from breaker to relays . should I separate grounds for relaysName:  0619191932.jpg
Views: 259
Size:  27.7 KB and compressors?
rickywideglide is offline   Reply With Quote
Old 06-20-2019, 02:25 PM   #4
SCOTI
Registered User
 
SCOTI's Avatar
 
Join Date: Apr 2001
Location: DALLAS,TX
Posts: 22,064
Re: air bag compressors tripping breaker

Quote:
Originally Posted by rickywideglide View Post
I followed schematic shown,6 ga wire is about 7 feet from breaker to relays . should I separate grounds for relays and compressors?
I'll look @ my schematic but I remember tying my grounds together for the comps & relays. I do however have 'over-kill' as far the remainder of my GROUND system:

Engine block to frame = Each side of motor has 4ga batt cable to the frame (L&R rails ground to block).
BATT @ PASS rail & cab (relocated battery).
Frame rails to core support = 4ga (again, both sides).
Cab to frame rails = 4ga (both sides).
Rear x-member welded to rails.
__________________
67SWB-B.B.RetroRod
64SWB-Recycle
89CCDually-Driver/Tow Truck
99CCSWB Driver
All Fleetsides
@rattlecankustoms in IG

Building a small, high rpm engine with the perfect bore, stroke and rod ratio is very impressive.
It's like a highly skilled Morrocan sword fighter with a Damascus Steel Scimitar.....

Cubic inches is like Indiana Jones with a cheap pistol.
SCOTI is offline   Reply With Quote
Old 06-20-2019, 06:57 PM   #5
PGSigns
Senior Member
 
PGSigns's Avatar
 
Join Date: Jan 2011
Location: Hayes Va
Posts: 4,569
Re: air bag compressors tripping breaker

Run a dedicated round and see if that fixes it.
Jimmy
__________________
60 to 66 Chevy and GMC window decals
http://67-72chevytrucks.com/vboard/s...d.php?t=661131
Good friends, good food and a hotrod what else do you need?
1966 BBW long fleet Daily driver
1965 BBW short fleet Sold and going to a good home
1965 Suburban
2003 3500 Duramax
2005 Ultra Classic
PGSigns is offline   Reply With Quote
Old 06-22-2019, 08:16 AM   #6
rickywideglide
Registered User
 
rickywideglide's Avatar
 
Join Date: Jun 2013
Location: mechanicsville,md
Posts: 360
Re: air bag compressors tripping breaker

thanks for replies, gonna mess with it this weekend
rickywideglide is offline   Reply With Quote
Old 06-29-2019, 07:02 PM   #7
rickywideglide
Registered User
 
rickywideglide's Avatar
 
Join Date: Jun 2013
Location: mechanicsville,md
Posts: 360
Re: air bag compressors tripping breaker

ending up changing 60 amp circuit breaker with a better brand,went to lower psi pressure switch,been working like it should,still gonna add better ground from batt. to frame
rickywideglide is offline   Reply With Quote
Reply

Bookmarks


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -4. The time now is 09:26 AM.


Powered by vBulletin® Version 3.8.11
Copyright ©2000 - 2024, vBulletin Solutions Inc.
Copyright 1997-2022 67-72chevytrucks.com