Old 10-05-2025, 12:03 PM   #1
TxGoats
Registered User
 
Join Date: Mar 2008
Location: College Station Texas
Posts: 42
1966 C10 with an electrical gremlin- help

Howdy folks, long time member but I’ve been away a few years. I picked up a ‘66 C10 that had been sitting many years. Have it running great with a 350 Crate motor, new bed, suspension, cab seals, body mounts, new seat cover and flooring. It’s mostly rust free except the driver door rocker. I love it, I have also restored the old Clardy Jet Star under dash air but I have an electrical gremlin I can’t figure out. Here are the particulars:
63 amp one wire alternator
New battery, ignition switch, restored wiring from ignition to starter, new ground straps, new cables.
Issues:
Starter will intermittently not start regardless if it’s hot or cold when starting but will always start with a remote starter.
Voltage shows 14 volts at the fuse box when started and alternator excited but when I turn on my headlights it drops to 11.3 volts but the battery doesn’t drop but maybe a tenth of a volt and turning on the ac is worse. I’ve disconnected each fuse and no changes, disconnected the wiring to the back lights, no change.
Any idea where to go from here? Time to just rewire this old guy?
Thanks for any helpful advise.
TxGoats is offline   Reply With Quote
Old 10-05-2025, 01:25 PM   #2
64 K10 Stepside Guy
Registered User
 
Join Date: Oct 2024
Location: Prague, CZ
Posts: 3
Re: 1966 C10 with an electrical gremlin- help

If it does crank slow or at least tries to turn, then the battery - although new - does not have the capacity to turn the engine and you should check the capacity of the battery - not just the voltage. Maybe missing water if not maintenance free...
If it does not do anything, check the ground wire and the wire to the starter - incl. connections to the battery. If the voltage drops to 11,3 when the engine is running, it would be the regulator to check.
If you pull all fuses without changing the situation, the wiring should not be the issue.
64 K10 Stepside Guy is offline   Reply With Quote
Old 10-05-2025, 02:53 PM   #3
TxGoats
Registered User
 
Join Date: Mar 2008
Location: College Station Texas
Posts: 42
Re: 1966 C10 with an electrical gremlin- help

Starter cranks strong so battery is good. With the engine off and turning headlights on I get a drop from 12.3 volts to 9.3, same with the blower on the air conditioner. Battery voltage shows almost zero change when lights are turned on and engine is running it only effects the voltage at the fuse box. Thanks for your input
TxGoats is offline   Reply With Quote
Old 10-05-2025, 04:01 PM   #4
bonehead
Registered User
 
bonehead's Avatar
 
Join Date: Jun 2007
Location: Charlotte, NC
Posts: 566
Re: 1966 C10 with an electrical gremlin- help

Those types of problems are usually caused by poor or missing grounds. Make sure you have three solid grounds: engine to frame, frame to body, battery neg to body. Check them out first. Good luck, BH
__________________
1980 C-10 Silverado SWB - gone
1961 C-10 custom cab LWB -gone
1966 C-10 custom cab LWB -gone
current truck:
1966 C-10 Panel SWB
...….___________
..…./______ /__{\___
..…/__(O)__/__/_(O)_/
bonehead is offline   Reply With Quote
Old 10-05-2025, 09:09 PM   #5
DPowers
One foot in front of the other
 
DPowers's Avatar
 
Join Date: Aug 2008
Location: Parrottsville, TN
Posts: 5,600
Re: 1966 C10 with an electrical gremlin- help

Run a hot wire from battery to the horn relay. Should take care of the intermittent no start.
DPowers is offline   Reply With Quote
Old 10-05-2025, 10:13 PM   #6
bhap
Senior Member
 
bhap's Avatar
 
Join Date: Mar 2006
Location: Pittsburgh, PA
Posts: 308
Re: 1966 C10 with an electrical gremlin- help

Check out Madelectrical.com. They have an improved wiring diagram that will give you some good ideas for configuring relays for headlights and other big users of electricity. I would also check the connections in the fuse bix - are they clean or crusty? When I redid my wiring, I kept most of the stock connections, but used headlight switch to power a relay at a fron distribution bar so headlight switch only carried minimal amps - only enough to trigger relay.
bhap is offline   Reply With Quote
Old 10-05-2025, 10:47 PM   #7
TxGoats
Registered User
 
Join Date: Mar 2008
Location: College Station Texas
Posts: 42
Re: 1966 C10 with an electrical gremlin- help

Quote:
Originally Posted by bhap View Post
Check out Madelectrical.com. They have an improved wiring diagram that will give you some good ideas for configuring relays for headlights and other big users of electricity. I would also check the connections in the fuse bix - are they clean or crusty? When I redid my wiring, I kept most of the stock connections, but used headlight switch to power a relay at a fron distribution bar so headlight switch only carried minimal amps - only enough to trigger relay.
Thanks, this is probably my best solution. Thanks for the info.
TxGoats is offline   Reply With Quote
Old 10-06-2025, 12:05 AM   #8
franken
Registered User
 
Join Date: Jun 2013
Location: Somewhere
Posts: 3,364
Re: 1966 C10 with an electrical gremlin- help

It sounds like you're describing a click or nothing from the solenoid issue w/o saying so. You might provide a description of what's happening.
Measure the voltage to ground from the solenoid S-terminal with the key in the start position when the problem happens.
Fixing a headlight issue won't solve a starter or solenoid issue.
franken is offline   Reply With Quote
Old 10-06-2025, 12:53 PM   #9
TxGoats
Registered User
 
Join Date: Mar 2008
Location: College Station Texas
Posts: 42
Re: 1966 C10 with an electrical gremlin- help

The ignition switch does 3 things. Starts, clicks but continued tries and it will start dropping voltage to about 10 volts or it does nothing and volts drop off the gauge. In both cases when it clicks, I can hit the remote start, which is connected via clips to the starter, and it starts, same when there is nothing when I turn the key. The starter always works with the remote starter that’s why I ruled out solenoid issues.
TxGoats is offline   Reply With Quote
Old 10-06-2025, 02:03 PM   #10
pdxhall
Senior Member
 
pdxhall's Avatar
 
Join Date: Mar 2011
Location: Tucson, Arizona
Posts: 2,103
Re: 1966 C10 with an electrical gremlin- help

Try checking the ignition switch. I had to change mine.
__________________
Sanity'66
http://67-72chevytrucks.com/vboard/s...d.php?t=515110
Long bed, Fleetside, Small back window

I've Done So Much, With So Little, For So Long, That Now I Can Do Anything With Nothing.
pdxhall is offline   Reply With Quote
Reply

Bookmarks


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -4. The time now is 07:51 PM.


Powered by vBulletin® Version 3.8.11
Copyright ©2000 - 2026, vBulletin Solutions Inc.
Copyright 1997-2025 67-72chevytrucks.com