#24 |
Senior Member
![]() Join Date: Jun 2002
Location: Kansas
Posts: 702
|
moneyguru, A friend did his shop with the radiant heat, so thats where I got the idea. If you type in "radiant heat" on your search engine you will get alot if info... I used 900' of 1/2" "pex" tubing (3, 300' lengths) buried in the concrete. A typical 40 gallon hot water tank, a manifold system made from copper tubing, and a $80.00 dollar recirculating pump made for this type of application. The pump uses only 65 watts. I also insulated the foundation around the outside (2' deep)
__________________
The kid Build threads: 51 Jimmy http://67-72chevytrucks.com/vboard/s...d.php?t=154951 http://67-72chevytrucks.com/vboard/s...d.php?t=219902 http://www.classictrucks.com/feature...uck/index.html 68 C10 http://67-72chevytrucks.com/vboard/s...ad.php?t=50348 |
![]() |
![]() |