Old 02-12-2015, 10:32 PM   #12
greg64
Registered User
 
greg64's Avatar
 
Join Date: Dec 2007
Location: Kimberley, BC, Canada
Posts: 799
Re: 400 sbc and electric fan help needed

Sev, one other improvement you can make is to take the voltage sense wire from the alternator, and run it to your new terminal strip. The benefit of this is that any loss in the wire from the alternator to the power strip will be compensated for by the regulator. So, you could end up with 15.4V at the alt, and 14.4V at the terminal strip.

I did this on both my trucks and it works, and charges great.
__________________
Greg
64 GMC Suburban - 283, NV3500, 14 bolt
77 C10 swb - 292, SM465, 12 bolt
greg64 is offline   Reply With Quote
 