Old 01-06-2006, 07:34 PM   #1
jay6891
Car Knocker
 
jay6891's Avatar
 
Join Date: May 2001
Location: jefferson,arkansas
Posts: 664
Blower motor quit

My heater blower motor just quit. Thought I blew a fuse. Checked it out everything ok. Unplugged the wire going to the blower and showing 14.7 volts with engine running and blower switch on high. Thought the motor finally burnt up. Just to be sure I hooked a temp wire from + side of battery to motor and the thing works. Now if I hook up the real wire to the fan and put a multimeter on it the reading is 0, if I unhook the wire and test again 14.7. I'm lost, any ideas.
__________________
68 c-10,91 sportside bed,350 .030 over,4 bolt,10-1 comp,2.05 intake/1.94 exhaust,1.6 Harland Sharp roller rockers,edelbrock rpm cam and intake w/750 carb, 700r4, 3.73 gears,Jacabbs Electronic Igntion w/Accel HEI distributer and super coil. ZR-1 roll pan, filled tailights. Blazer tank. Hidden hitch. 2 1/2" Flowmaster 40's. Parts bought but not installed>> ford 9" posi with disc. CCP front and rear lowering kit 4/5. Cab corners,foor boards,rockers, cab braces, Phatom grill, Painless wiring kit.
jay6891 is offline   Reply With Quote
Old 01-06-2006, 07:41 PM   #2
CraigS
Registered User
 
Join Date: Dec 2000
Location: Gresham, OR, USA
Posts: 106
Re: Blower motor quit

Look to see if your resistor pack is bad. I don't remember if the motor is switched on the ground side or the power side.
__________________
72 GMC K20, 454, TH350
00 GMC Yukon
66 Ford Bronco
CraigS is offline   Reply With Quote
Old 01-06-2006, 08:45 PM   #3
jay6891
Car Knocker
 
jay6891's Avatar
 
Join Date: May 2001
Location: jefferson,arkansas
Posts: 664
Re: Blower motor quit

I checked the resister (sp), voltage goes up as I come up on fan speeds. I'm pretty sure it is + switched. Will probably go get a fan motor but trying to figure out why it works when wired direct and wipes out all my voltage when plugged up through the factory harness.
__________________
68 c-10,91 sportside bed,350 .030 over,4 bolt,10-1 comp,2.05 intake/1.94 exhaust,1.6 Harland Sharp roller rockers,edelbrock rpm cam and intake w/750 carb, 700r4, 3.73 gears,Jacabbs Electronic Igntion w/Accel HEI distributer and super coil. ZR-1 roll pan, filled tailights. Blazer tank. Hidden hitch. 2 1/2" Flowmaster 40's. Parts bought but not installed>> ford 9" posi with disc. CCP front and rear lowering kit 4/5. Cab corners,foor boards,rockers, cab braces, Phatom grill, Painless wiring kit.
jay6891 is offline   Reply With Quote
Old 01-06-2006, 09:27 PM   #4
crazyred
yeeha
 
crazyred's Avatar
 
Join Date: Sep 2005
Location: Sherwood Park & Fort McMurray, Alberta
Posts: 72
Re: Blower motor quit

yepper, sounds like the resistor pack .... just a *note* i do believe that there is a fuse in that resistor pack for low and for Medium, high speed is just straight supply power and has a NO resistor and therefore connected after fuse in the resistor pack. i'd suggest to replace the pack and all should be good .... but if she craps out again well then you need to look at the blower motor. It's got too much fricton to turn freely and is therefore drawing too many amps and blowing the small fuse in the pack.
Attached Images
 
__________________
1969 GMC 910 97% rust free
2002 olds Alero
1986 New Yorker 4dr ... the new DD...My POS car... dude its got a turbo!!!

Don't drink and drive, you might spill something!!!

Daryl Kuchmak
crazyred is offline   Reply With Quote
Old 01-07-2006, 06:59 AM   #5
GMC Jim
Senior Member
 
GMC Jim's Avatar
 
Join Date: Dec 2002
Location: Portland, Oregon
Posts: 901
Re: Blower motor quit

according to the wiring diagram I have; the 'high' speed blower motor switch setting goes thru a relay. This relay is located on the inside of cab, right side, up alongside the glove compartment box............ Jim
__________________
'71 GMC;fleetside;PB/PS/AC/CC/402 Eng./Custom Paint/110,000act miles/3 fuel tanks(52gal).
GMC Jim is offline   Reply With Quote
Old 01-07-2006, 09:55 AM   #6
Billla
Account Suspended
 
Billla's Avatar
 
Join Date: Sep 2005
Location: Monroe, WA
Posts: 3,815
Re: Blower motor quit

I have a blower that runs, but on low only. I was planning on replacing the switch just as a "let's replace this and see what happens" thing...should I be looking at the resistor pack and/or relay instead?

I'm definitely not an auto electric whiz
Billla is offline   Reply With Quote
Old 01-07-2006, 12:44 PM   #7
CraigS
Registered User
 
Join Date: Dec 2000
Location: Gresham, OR, USA
Posts: 106
Re: Blower motor quit

Jay6891 - it's definitely not the motor if you can get it to run direct wired.
Billa - if you have low speed, you're resistor pack is OK. I'd check the switch/switch wiring.
GMCJim - are you sure you have the right year diagram? I have a 72GMC with no relay on the firewall. It's direct wired thru the switch on mine.
__________________
72 GMC K20, 454, TH350
00 GMC Yukon
66 Ford Bronco
CraigS is offline   Reply With Quote
Old 01-07-2006, 07:16 PM   #8
GMC Jim
Senior Member
 
GMC Jim's Avatar
 
Join Date: Dec 2002
Location: Portland, Oregon
Posts: 901
Re: Blower motor quit

Craig S.... My '71 GMC with factory air does have the relay ( I have replaced it!) Looks like trucks without air did not use the relay.... Also the standard fan used with heater only trucks draws 6.25 amps max ( 2550 - 2950 RPM).
The standard blower motor used with factory air draws 16.5 amps max ( 3700 RPM ) . Recalling previous messages regarding heater/air blower switch malfunctions; it appears that if the heavy duty ( air-cond) blower is used with the heater only installations, the amperage could damage the blower switch unless a relay was installed for the 'high' blower function. ( just my 2 cents ! ).............. Jim
__________________
'71 GMC;fleetside;PB/PS/AC/CC/402 Eng./Custom Paint/110,000act miles/3 fuel tanks(52gal).
GMC Jim is offline   Reply With Quote
Old 01-07-2006, 07:29 PM   #9
Tx Firefighter
Watch out for your cornhole !
 
Tx Firefighter's Avatar
 
Join Date: Jun 2003
Location: Azle, Texas
Posts: 14,162
Re: Blower motor quit

I've seen before, where a switch will pass enough current to light a test light or show full voltage, but not enough amperage to work the fan.

Jumper the switch itself and I bet you'l find the motor runs.
__________________
I'm on the Instagram- @Gearhead_Kevin
Tx Firefighter is offline   Reply With Quote
Old 01-07-2006, 08:38 PM   #10
jay6891
Car Knocker
 
jay6891's Avatar
 
Join Date: May 2001
Location: jefferson,arkansas
Posts: 664
Re: Blower motor quit

I was thinking of that today at work today Tx Firefighter. Took the switch apart and cleaned it and polished up the copper contacts. Not much to the switch though gotta love 1968 tech. Still same result. Anybody know which fuse it is in the fuse box. Can't read the writing anymore. Maybe losing the amperage in the fuse box contacts.
__________________
68 c-10,91 sportside bed,350 .030 over,4 bolt,10-1 comp,2.05 intake/1.94 exhaust,1.6 Harland Sharp roller rockers,edelbrock rpm cam and intake w/750 carb, 700r4, 3.73 gears,Jacabbs Electronic Igntion w/Accel HEI distributer and super coil. ZR-1 roll pan, filled tailights. Blazer tank. Hidden hitch. 2 1/2" Flowmaster 40's. Parts bought but not installed>> ford 9" posi with disc. CCP front and rear lowering kit 4/5. Cab corners,foor boards,rockers, cab braces, Phatom grill, Painless wiring kit.
jay6891 is offline   Reply With Quote
Reply

Bookmarks

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -4. The time now is 07:18 AM.


Powered by vBulletin® Version 3.8.11
Copyright ©2000 - 2024, vBulletin Solutions Inc.
Copyright 1997-2022 67-72chevytrucks.com