The 1947 - Present Chevrolet & GMC Truck Message Board Network







Register or Log In To remove these advertisements.

Go Back   The 1947 - Present Chevrolet & GMC Truck Message Board Network > 47 - Current classic GM Trucks > The 1967 - 1972 Chevrolet & GMC Pickups Message Board

Web 67-72chevytrucks.com


Reply
 
Thread Tools Display Modes
Old 12-11-2012, 10:41 AM   #1
oilyrag80
Registered User
 
oilyrag80's Avatar
 
Join Date: Jul 2006
Location: Tucson Az
Posts: 1,695
how much fan clearance?

Im running a 454 with a long pump in my 68 swb project and i finally installed
a 4row rad and the clutch is very close to raidiator. How much clearance is enough? It looks like i have only 3/8 ths or so of clearance.
Thanks in advance
Attached Images
 
oilyrag80 is offline   Reply With Quote
Old 12-11-2012, 12:42 PM   #2
Stocker
20' Daredevil (Ret)
 
Stocker's Avatar
 
Join Date: May 2003
Location: Jefferson State
Posts: 13,722
Re: how much fan clearance?

That would make me nervous. I don't think I'd trust anything closer than about an inch. I wonder if twin electrics -- one on either side of the water pump -- might be a better setup.
__________________
- Mike -

1972 K20 LWB 350/350/205

RIP El Jay
Stocker is offline   Reply With Quote
Old 12-11-2012, 01:23 PM   #3
davepl
Registered User
 
davepl's Avatar
 
Join Date: Aug 2006
Location: Redmond, WA
Posts: 6,332
Re: how much fan clearance?

Depends how tight the mounts and everything else is, it's pretty close. Keep in mind that the depth of the fan into the shroud is important for cooling, so that it doesn't just churn around its own air.

Normally you want about exactly half of the fan within the shroud.
__________________
1970 GMC Sierra Grande Custom Camper - Built, not Bought
1969 Pontiac 2+2 427/390 4-speed Coupe
1969 Pontiac 2+2 427/390 4-speed Convertible
davepl is offline   Reply With Quote
Old 12-11-2012, 01:27 PM   #4
BMERDOC
Registered User
 
BMERDOC's Avatar
 
Join Date: Jun 2011
Location: Richmond,Va
Posts: 2,934
Re: how much fan clearance?

Quote:
Originally Posted by davepl View Post
Depends how tight the mounts and everything else is, it's pretty close. Keep in mind that the depth of the fan into the shroud is important for cooling, so that it doesn't just churn around its own air.

Normally you want about exactly half of the fan within the shroud.
Text book explaination! Gets my vote.
__________________
Nick Carter
1967 C10 Short bed Fleetside
Project Cheap Thrills!
2WD C10 Modern/Performance Alignments
Easiest Alignment Ever!
BMERDOC is offline   Reply With Quote
Old 12-11-2012, 02:38 PM   #5
Stocker
20' Daredevil (Ret)
 
Stocker's Avatar
 
Join Date: May 2003
Location: Jefferson State
Posts: 13,722
Re: how much fan clearance?

Quote:
Originally Posted by davepl View Post
Depends how tight the mounts and everything else is
I agree, but everything that is tight enough now can loosen up a bit over time. It wouldn't take much for today's 3/8" to become tomorrow's expensive crunch.
__________________
- Mike -

1972 K20 LWB 350/350/205

RIP El Jay
Stocker is offline   Reply With Quote
Old 12-11-2012, 02:46 PM   #6
oilyrag80
Registered User
 
oilyrag80's Avatar
 
Join Date: Jul 2006
Location: Tucson Az
Posts: 1,695
Re: how much fan clearance?

yea i think its to close, is there such a thing as a shorter fan clutch?
I dont want to run electric if at all possible. I wonder what the factoy clearance is
with short pump because everthing else is stock.
There are no fenders mounted but there is almost no movement with the poly bushings.
Thanks
oilyrag80 is offline   Reply With Quote
Old 12-11-2012, 05:33 PM   #7
Frkypunk70
Registered User
 
Frkypunk70's Avatar
 
Join Date: Mar 2010
Location: Scranton,Pa
Posts: 423
Re: how much fan clearance?

Perfect canidate for jeep electric fan install.
Posted via Mobile Device
__________________
"When I die, I want to go peacefully like my Grandfather did, in his sleep -- not screaming, like the passengers in his car. "
Frkypunk70 is offline   Reply With Quote
Old 12-11-2012, 06:40 PM   #8
Stocker
20' Daredevil (Ret)
 
Stocker's Avatar
 
Join Date: May 2003
Location: Jefferson State
Posts: 13,722
Re: how much fan clearance?

Quote:
Originally Posted by oilyrag80 View Post
I wonder what the factoy clearance is with short pump because everthing else is stock.
I googled it, found same info on a couple other forums -- 1 9/16" (1.5625") difference, long pump to short pump.
__________________
- Mike -

1972 K20 LWB 350/350/205

RIP El Jay
Stocker is offline   Reply With Quote
Old 12-11-2012, 06:46 PM   #9
MikeyMan
Registered User
 
Join Date: May 2008
Location: S.W. Chicago, IL.
Posts: 317
Re: how much fan clearance?

Quote:
Originally Posted by oilyrag80 View Post
I wonder what the factoy clearance is
with short pump because everthing else is stock.
There are illustrations with the water pump dimensions. I remember seeing it somewhere when I was looking up my WP. You could just do the math and see the difference between long vs short. If I recall, it's not too much, like a little over an inch.
Short pump would cause all kinds of headaches lining up pullys and accessories you already have.

I just replaced my water pump in my 72. Mine looks exactly like yours. I have a later 350 with long pump. Same pass. side Alt mount & bracket, and power steering bracket pivot that goes through WP on drivers side.
I have 2 inches between fan clutch and my stock/skinny radiator. I'm not sure about the frame location of my motor, though. It was swapped when I got it. VIN says it was a 6, bracket on frame says Manual Trans. It came with 350/TH350.

Yours seems too close. Do you intend to use a shroud?
MikeyMan is offline   Reply With Quote
Old 12-11-2012, 06:47 PM   #10
MikeyMan
Registered User
 
Join Date: May 2008
Location: S.W. Chicago, IL.
Posts: 317
Re: how much fan clearance?

Quote:
Originally Posted by Stocker View Post
I googled it, found same info on a couple other forums -- 1 9/16" (1.5625") difference, long pump to short pump.
Math Wiz!
MikeyMan is offline   Reply With Quote
Old 12-11-2012, 07:17 PM   #11
oilyrag80
Registered User
 
oilyrag80's Avatar
 
Join Date: Jul 2006
Location: Tucson Az
Posts: 1,695
Re: how much fan clearance?

Quote:
Originally Posted by Stocker View Post
I googled it, found same info on a couple other forums -- 1 9/16" (1.5625") difference, long pump to short pump.
wow thats more than i thought i guess i shouldent have sold my big block short pump stuff. Ill find another swp setup that seems to be the best solution.
I need to get this right because its hard to keep a big block cool around here in july! Thanks
oilyrag80 is offline   Reply With Quote
Old 12-11-2012, 07:28 PM   #12
ole dollor
Registered User
 
ole dollor's Avatar
 
Join Date: May 2012
Location: Anton, Texas
Posts: 2,364
Re: how much fan clearance?

you could go with a flex fan ,or straight drive fan, but i am not a fan of either. the way it is now if you had to stop real quick ,your fan may hit the rad.
ole dollor is offline   Reply With Quote
Reply

Bookmarks

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -4. The time now is 09:34 PM.


Powered by vBulletin® Version 3.8.11
Copyright ©2000 - 2024, vBulletin Solutions Inc.
Copyright 1997-2022 67-72chevytrucks.com