any new direct fit parallel flow condensers for factory fit AC
Hi everyone. I recently got my truck back on the road and converted my AC system to r134. I recently had a post about high pressures with a low charge amount. anyways, I have a new aluminum A6 compressor, new lines, new dryer flushed evap. and condenser and calibrated my POA valve for r134 and reusing my expansion valve. Like I said in the previous post I was get high pressure with a low charge. So I thought it might be the expansion valve. but since I've evacuated the system again, I think I'm going to go ahead and replaced the condenser to a parallel flow to help get the pressures down.
I did a search about replacement condensers, but they all seem several years old. Does anyone know of a direct replacement parallel flow condenser for a factory AC setup. So far, I think I found one from Old Air Products that will fit with some brackets and supplied lines like this. but thought I should throw this out there. Thanks https://www.oldairproducts.com/produ...enser-assembly |
07-11-2024, 09:30 PM | #2 | |
Senior Member
Join Date: Nov 2018
Location: Waterford California
Posts: 2,626
|
Re: any new direct fit parallel flow condensers for factory fit AC
Quote:
I enjoy Ice Cold A/C as a note I also replaced the A/C evaporator and heater core, lots of flow obstructing debris found in there. |
|
07-11-2024, 09:47 PM | #3 |
Senior Member
Join Date: Apr 2016
Location: Cypress, TX
Posts: 3,859
|
Re: any new direct fit parallel flow condensers for factory fit AC
Do you have a link for parallel flow condenser on LMC's website? I am not able to find it and can't find it in the printed catalog either.
|
07-11-2024, 10:40 PM | #4 |
Senior Member
Join Date: Nov 2018
Location: Waterford California
Posts: 2,626
|
Re: any new direct fit parallel flow condensers for factory fit AC
I could not find it either so I went out and looked....mines is not a parallel flow it's the same as the LMC Catalog . Old Air does or did sell individual component's.. give them a call as they say they are a bolt in fit.
https://www.oldairproducts.com/produ...mplete-package |
07-12-2024, 01:03 AM | #5 | |
Registered User
Join Date: Dec 2005
Location: Kalifornia
Posts: 354
|
Re: any new direct fit parallel flow condensers for factory fit AC
Quote:
|
|
07-12-2024, 01:13 AM | #6 |
Active Member
Join Date: Feb 2016
Location: vallejo, ca
Posts: 160
|
Re: any new direct fit parallel flow condensers for factory fit AC
I plan on replacing the exspansion valve regardless at this point since the system is empty and the valve is pretty cheap.
One question since we're talking about the exspansion valve. Where is the correct position for the capillary bulb to be mounted? If anyone has pictures that would be good. If I remember correctly, it's actually inside the case, but I want to say I think I've seen some mounted just outside the case. |
07-14-2024, 09:48 PM | #7 | |
425hp409
Join Date: Oct 2008
Location: Prosper Texas
Posts: 841
|
Re: any new direct fit parallel flow condensers for factory fit AC
Quote:
__________________
Charles 68 SWB, Dad bought new, now 396 & factory ac 64 Impala SS, 409 425HP, 4 speed AC 64 Bel Air Wagon, 400 Small Block 57 Bel Air all original 283 w/Factory Air 77 GMC Sprint, 454/425HP 67 Olds 442, all original 90 ZR1 Corvette |
|
07-15-2024, 02:41 AM | #8 |
Active Member
Join Date: Feb 2016
Location: vallejo, ca
Posts: 160
|
Re: any new direct fit parallel flow condensers for factory fit AC
Thanks for the reply. But does it matter where on the evaporator outlet tube? Does it need to be inside the evaporator cover ( more work) Or can it be just outside the cover ( less work)? Wrapped of course. Thanks
|
07-15-2024, 03:11 AM | #9 |
Senior Member
Join Date: Dec 1999
Location: Southern California
Posts: 2,880
|
Re: any new direct fit parallel flow condensers for factory fit AC
The evaporator exit tube goes directly out of the case. There is no place to put it inside the case. The bulb just needs to be put on the exit of evaporator. Not a big deal.