#19 |
Registered User
![]() Join Date: Apr 2009
Location: New Freedom Pa.
Posts: 1,335
|
Re: TBI bogging?
The "westergate" link is wrong about one thing, The timing conector is in the harness is on the firewall as pictured in this photo. not over by the blower motor . I'm not sure what you are disconnecting that is making the engine not start. My guess is that you are running now with the engine in "Open-Loop" mode which are the ECM presets. The problem with this is , it does not use any sensor input when warmed up. So your fuel curve, timing and idle speed are not being fine tuned. If everything is working as it should , a TBI engine is a dream to drive.
|
![]() |
![]() |