The 1947 - Present Chevrolet & GMC Truck Message Board Network







Register or Log In To remove these advertisements.

Go Back   The 1947 - Present Chevrolet & GMC Truck Message Board Network > 47 - Current classic GM Trucks > The 1973 - 1987 Chevrolet & GMC Squarebody Pickups Message Board

Web 67-72chevytrucks.com


Reply
 
Thread Tools Display Modes
Old 05-18-2016, 02:23 PM   #1
IdahoMan
Registered User
 
Join Date: Oct 2014
Location: IDaho
Posts: 89
Cab construction question (elec. ground)

Hello.

I will putting 50A Max sockets behind my seats and have a ground question.

How exactly is the cab grounded? The one place I know of is the bolt on the firewall where it is connected via a braided strap to the back right-side of the engine. But as far as the cab's construction goes, how is it assembled so the whole thing is grounded and at the same time not a rust-risk (if the cab is made of seperate pieces, the bare metal has to be connected electrically somehow)? For assembly/repair is the cab welded, then seam-sealed, then painted or something like that?

Below is the speaker corner where I would like to put a high-amp ground bolt. Will that work? (Yes, I'll be upgrading all my grounds)

Thank you.


Sincerely,
IM
Attached Images
 
IdahoMan is offline   Reply With Quote
Old 05-18-2016, 03:45 PM   #2
Keith Seymore
Registered User
 
Keith Seymore's Avatar
 
Join Date: May 2009
Location: Motor City
Posts: 9,213
Re: Cab construction question (elec. ground)

The cab is grounded via a braided cable to the engine and to the vehicle frame (the pickup box is also grounded to the frame).

The cab is comprised of separate pieces welded together and with seam sealer, as you have surmised, but because of the welding you have ground as if the cab was fabricated from one solid piece of metal.

Back then ground was achieved by shooting a bolt (with a star washer) through the paint, attaching the braided cable. You can imagine how that works out long term...

These days we use a copper weld stud attached to the sheet metal, which allows for an unpainted surface for continuity but without the corrosion concerns.

K
__________________
Chevrolet Flint Assembly
1979-1986
GM Full Size Truck Engineering
1986 - 2019
Intro from an Old Assembly Guy: http://67-72chevytrucks.com/vboard/s...d.php?t=342926
My Pontiac story: http://forums.maxperformanceinc.com/...d.php?t=560524
Chevelle intro: http://www.superchevy.com/features/s...hevy-chevelle/
Keith Seymore is online now   Reply With Quote
Old 05-18-2016, 04:00 PM   #3
IdahoMan
Registered User
 
Join Date: Oct 2014
Location: IDaho
Posts: 89
Re: Cab construction question (elec. ground)

Whoops, forgot to add that my truck is a 1981.
IdahoMan is offline   Reply With Quote
Old 05-18-2016, 05:35 PM   #4
IdahoMan
Registered User
 
Join Date: Oct 2014
Location: IDaho
Posts: 89
Re: Cab construction question (elec. ground)

Quote:
The cab is grounded via a braided cable to the engine and to the vehicle frame (the pickup box is also grounded to the frame).
This seem like a silly question, but how is it grounded to the frame? With the bolt that holds the cab to the frame? If so, isn't there a rust risk? (I'm a rust paranoid)


Quote:
Back then ground was achieved by shooting a bolt (with a star washer) through the paint, attaching the braided cable. You can imagine how that works out long term...

These days we use a copper weld stud attached to the sheet metal, which allows for an unpainted surface for continuity but without the corrosion concerns.

K
Thank you.

Last edited by IdahoMan; 05-18-2016 at 05:46 PM.
IdahoMan is offline   Reply With Quote
Old 05-19-2016, 12:21 PM   #5
Keith Seymore
Registered User
 
Keith Seymore's Avatar
 
Join Date: May 2009
Location: Motor City
Posts: 9,213
Re: Cab construction question (elec. ground)

Quote:
Originally Posted by IdahoMan View Post
This seem like a silly question, but how is it grounded to the frame? With the bolt that holds the cab to the frame? If so, isn't there a rust risk? (I'm a rust paranoid)




Thank you.
The braided cable makes a more direct ground, not trusting the cab/body bolts. A similar technique is used to ground hoods and decklids (for radio interference protection), preferring a more direct ground and bypassing the hinge attaching bolts. In today's vehicles, with much higher electrical content (and much higher downside to poor grounds) the body is grounded to the chassis in multiple locations.

The whole "star washer"/breaking the paint idea was a terrible idea in terms of corrosion. That's how the taillamps on the stepside were grounded. The rust was so bad that every spring I would pull the tailgate, taillamps and brackets off and repaint them and reinstall. After I did that the turn signals didn't work - because I lost the ground. I ended up adding a short jumper wire from the bulb socket directly to the frame rail, which solved the problem.

I have the same problem on my open car trailer; I'd really like to ground to clean, bare metal but the problem is clean, bare metal rusts. The two requirements are at odds with one another.

K
__________________
Chevrolet Flint Assembly
1979-1986
GM Full Size Truck Engineering
1986 - 2019
Intro from an Old Assembly Guy: http://67-72chevytrucks.com/vboard/s...d.php?t=342926
My Pontiac story: http://forums.maxperformanceinc.com/...d.php?t=560524
Chevelle intro: http://www.superchevy.com/features/s...hevy-chevelle/

Last edited by Keith Seymore; 05-19-2016 at 12:27 PM.
Keith Seymore is online now   Reply With Quote
Old 05-20-2016, 12:22 AM   #6
gmachinz
Account Suspended
 
Join Date: Jun 2011
Location: Des Moines, IA.
Posts: 4,143
Re: Cab construction question (elec. ground)

I just starting replicating new rear lamp harnesses and the harness on my 86 K10 has its tail light ground inside the LH tail lamp pocket on the inner box structure. All the grounds for the side markers and turn signal bulbs share this rather inadequate 16ga ground. On my own truck builds, I stud weld a 10mm stud to the rear frame and from there I run my rear bulb grounds as well as grounding the box too from underneath....so I retain the original tail lamp ground but with a 14ga wire and I run my grounds to my grounding stud on frame which then has a lead running to a floor brace of the box with a self grounding serraded machine screw.
gmachinz is offline   Reply With Quote
Old 05-20-2016, 02:11 AM   #7
wilkin250r
Registered User
 
wilkin250r's Avatar
 
Join Date: Sep 2010
Location: Lake Tahoe, Nevada
Posts: 755
Re: Cab construction question (elec. ground)

If it was me, I'd jump in with both feet.

Let's say worst case scenario you get a lousy connection with a 1V drop across it (which is a HUGE voltage drop across a connection), and by some miracle you're still pulling 50 amps through that spot. That results in 50 watts of power loss, 50 watts of heat.

50W in a transistor will have that sucker smoking within seconds, 50W of power loss in a transformer will melt the insulation of the wires. But 50W of power in a solid metal chassis with a surface area of a hundred square feet? Drop in the bucket. It'll create a warm spot, and nothing more. And that's worst case scenario.

So you build it, you test it. If the worst-case scenario comes true, you upgrade your ground path, maybe add a braided ground strap, and the problem disappears.

As long as you're grounding to the metal of the cab, I wouldn't hesitate even a little bit, because even if the rest of the ground path to frame and battery and engine block are all terrible, they're easy to fix.
__________________
I know a little about cars, but if you have a question about electricity or sport quads, I'm your man!!!
wilkin250r is offline   Reply With Quote
Old 05-20-2016, 12:16 PM   #8
N2TRUX
Happy to be here
 
N2TRUX's Avatar
 
Join Date: Mar 2000
Location: Cypress, TX
Posts: 39,023
Re: Cab construction question (elec. ground)

Your best bet is to add a true ground circuit. On my last build, I pulled everything under the hood and cleaned, sanded, and painted every part I removed. Even though I sanded every ground point to raw metal, I still had issues. I ran an extra ground wire from the battery to the block, and down to the frame. It was amazing how much better everything electrical worked.
__________________
Follow me on Facebook and Instagram @N2trux.com

Articles-

"Jake" the 84 to 74 crewcab

"Elwood" the77_Remix

85 GMC Sierra "Scarlett"

"Refining Sierra"
N2TRUX is offline   Reply With Quote
Old 05-20-2016, 03:32 PM   #9
jetmech85
Registered User
 
Join Date: Sep 2014
Location: Texas
Posts: 215
Re: Cab construction question (elec. ground)

If you attach your bonding strap (ground) to a bare metal spot then seal it with a sealant that dries firm it can then be painted to prevent corrosion. The sealant will prevent paint from wicking under the attaching hardware thereby compromising the connection.
jetmech85 is offline   Reply With Quote
Reply

Bookmarks

Tags
cab, ground, grounding


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -4. The time now is 08:48 AM.


Powered by vBulletin® Version 3.8.11
Copyright ©2000 - 2024, vBulletin Solutions Inc.
Copyright 1997-2022 67-72chevytrucks.com