Register or Log In To remove these advertisements. |
|
|
|
Thread Tools | Display Modes |
07-27-2024, 04:52 PM | #1 |
Senior Member
Join Date: Dec 2007
Location: Dumas, Texas
Posts: 210
|
Taillight Fuel Filler Hose Routing
I'm trying to route the filler hose from my tail light filler to my rear mounted tank.
I have a sniper fuel tank with the filler hole in the top lower left corner. I have both a straight filler neck for the tank and one like the picture. Both are 2" in diameter. I plan on going between the bed and the frame rail the up to the filler in the tail light. I have thought about reducing down to a 1" filler (as that is the size of the end in the tail light. Then get a long filler hose with a 90 degree end to connect. My concern is enough slope so all the fuel drains into the tank. Can anyone who has plumbed a tail light filler to a rear mounted tank give me some advise? Thanks Larry |
07-28-2024, 03:35 PM | #2 |
Registered User
Join Date: Sep 2020
Location: Cleveland, Ohio
Posts: 546
|
Re: Taillight Fuel Filler Hose Routing
I originally had a 2" set-up, but I could not get the hose to bend tight enough. I had to go to 1.5" diameter. I bought and adapter to go from the 2" to 1.5" from ICT Billet if I recall.
|
07-29-2024, 10:10 AM | #3 |
Senior Member
Join Date: Dec 2007
Location: Dumas, Texas
Posts: 210
|
Re: Taillight Fuel Filler Hose Routing
Thanks.
Which neck did you use on the tank and what did you use to connect from there to the filler neck? Thanks |
07-29-2024, 04:54 PM | #4 |
Registered User
Join Date: Sep 2020
Location: Cleveland, Ohio
Posts: 546
|
Re: Taillight Fuel Filler Hose Routing
I am using a Boyd tank and LS Fabrication rear fuel door set-up. I used these hoses:
https://www.amazon.com/gp/product/B0...?ie=UTF8&psc=1 |
08-11-2024, 10:39 AM | #5 | |
Registered User
Join Date: Oct 2015
Location: Upland, CA
Posts: 39
|
Re: Taillight Fuel Filler Hose Routing
Quote:
Also, do you have 2.0" at the tank or at the tail light filler?
__________________
Tony J |
|
08-11-2024, 11:12 AM | #6 |
Registered User
Join Date: Sep 2020
Location: Cleveland, Ohio
Posts: 546
|
Re: Taillight Fuel Filler Hose Routing
Both allow for bends, but the 2" I could not get it to bend enough to go from tail light to the tank. The 1.5" allowed it without too much of an issue, which is why I went that way. The tail light is 1.5". The hose is 1.5", then I have an adapter right near the tank that adapts the 1.5" hose to 2" as the inlet on the tank is 2".
|
08-11-2024, 12:18 PM | #7 |
Senior Member
Join Date: Dec 2007
Location: Dumas, Texas
Posts: 210
|
Re: Taillight Fuel Filler Hose Routing
Joyridin- the hose works perfect.
One question- did you connect the hose to the filler fitting in the housing? If so did you clamp it or just slide it on? Like you stated the hose is 1.5" and the hole is 1.5", so there is no way to get the hose through with s clamp. I'm thinking putting sealer on the fitting the just sliding the hose on and call it good. |
08-11-2024, 02:32 PM | #8 | |
Registered User
Join Date: Sep 2020
Location: Cleveland, Ohio
Posts: 546
|
Re: Taillight Fuel Filler Hose Routing
Quote:
|
|
Bookmarks |
|
|