Quote:
Originally Posted by kglowacky
Thinking of replacing my current junkyard Dodge dual cooling fans with a new set. I would like to get some that draw less amps than my current ones. Not sure what mine draw but when they turn on it drops the amp gauge below 11. Anyone using a set that bolts right in and are happy with them? would like a one piece 2-unit bolt in. Again got these out of a junkyard 5 years ago and the alt. works fine while running everything else until they come on. During the day all good at night when it drops. Had alt checked it is 110 amps. all good.
Thanks
Can someone move this to electrical. Thanks
|
Changing to a different fan probably won't cure your voltage drop problem.. Fans that have good cfm ratings draw about 20 amps each. That's 40 amps just for the fans. They should be relay activated and the wiring should be no less than 10 gauge.. If the fans are wired on separate circuits, 12 gauge will work.. If your alternator is less than 85 - 90 amps output, that's part of the problem..
My truck had a 78 amp alternator when a previous owner converted to internal regulator. I installed dual fans and the 78 amp alternator would just barely keep up.. At night with lights and AC running, it simply wasn't enough alternator.. I switched to a 100 amp alternator, 8 gauge charging wire to the battery and problem solved..