Register or Log In To remove these advertisements. |
|
|
|
Thread Tools | Display Modes |
10-21-2024, 03:28 PM | #1 |
Senior Member
Join Date: Oct 2013
Location: Santa Paula, CA
Posts: 622
|
1973 k10 intellitronix fuel gauge issue
Hey everyone, i recently performed ls swap on my buddy's 73 k10. I also installed intellitronix analog gauges. I'm having issues with no voltage meter reading at all. Fuel level gauge is reading different readings all of the time. Sometimes needle is pointing straight down, sometimes 3/4 tank, sometimes 1/4 tank. All of this happens within a few minutes of driving. I ran out of gas on Friday and was stranded for 2 hours. Gauge was reading 1/4 tank. I'm using 87 tbi tank, 87 tbi sending unit with 255 lph walbro pump. Sending unit wiring is as follows. Sending unit ground with eyelet to frame rail clean no piant star washer nut and bolt. Pump harness 2 wire pigtail is fitech fuel pump relay wire to positive wire of fuel pump, negative wire of fuel pump is connected to signal wire of intellitronix fuel level gauges. Intellitronix fuel level gauge ground wire is connected to frame rail clean no piant star washer nut and bolt tight. Frame rail grounded to negative post of battery. Heavy duty ground straps from both cylinder heads to framerail, frame rail to battery negative post, cab to frame rail with ground straps. Fuel tank to frame rail with ground wire clean no paint and tight with star washer. Oil pressure gaugereads correctly and so does water temp gauge. Speedometer needs calibration and so does tach. But voltmeter gauge shows nothing all the time no matter what. Any help??
__________________
1972 C/10 LWB - Mine 1964 C/10 LWB - My Dad's Instagram: Mike_The_Grad |
10-21-2024, 03:38 PM | #2 |
Senior Member
Join Date: Oct 2013
Location: Santa Paula, CA
Posts: 622
|
Re: 1973 k10 intellitronix fuel gauge issue
I also rewired entire vehicle with american autowire classic update series kit. Have zero issues. All lights work. Engine runs great have power everywhere it's needed. I also used my test meter to check continuity on gauge fuel gauge circuit and fuel pump and fuel tank sending unit circuit. I have continuity from fuel pump positive to fuel pump negative wire harness from sending unit. I have continuity from fuel pump positive to vehicle frame negative. I have continuity from tank to frame. I don't have continuity from fuel pump negative to vehicle frame. But I do have resistance value of 83.7 ohms. From negative of fuel pump to vehicle frame. How can I have resistance value but no continuity? I'm not electrician. But I can listen and follow instructions. This is the first time I've ever had any issues with a gauge not working properly. And I've rewired at least 10 trucks. Installed dakota digital, classic instruments, new vintage and intellitronix digital gauges, ls swap, sbc engines, some with fuel injection. Trouble shooted stock gauges and vehicle wiring. But this one has me stumped.
__________________
1972 C/10 LWB - Mine 1964 C/10 LWB - My Dad's Instagram: Mike_The_Grad |
10-21-2024, 05:13 PM | #3 |
Registered User
Join Date: Mar 2022
Location: Surrey BC
Posts: 894
|
Re: 1973 k10 intellitronix fuel gauge issue
>negative wire of fuel pump is connected to signal wire of intellitronix fuel level gauges<
that does not sound right |
10-21-2024, 08:04 PM | #4 |
Senior Member
Join Date: Oct 2013
Location: Santa Paula, CA
Posts: 622
|
Re: 1973 k10 intellitronix fuel gauge issue
I agree 100% but where do I pull my fuel level sender signal from then? Key on sending unit wire disconnected from the gauges. I get
6.7Mv against vehicle ground.
__________________
1972 C/10 LWB - Mine 1964 C/10 LWB - My Dad's Instagram: Mike_The_Grad |
10-22-2024, 12:27 AM | #5 |
Registered User
Join Date: Mar 2022
Location: Surrey BC
Posts: 894
|
Re: 1973 k10 intellitronix fuel gauge issue
I know nothing about your specific gauges, but the '87 tank works like this, so unless you are supposed to change sender units your gauges must work like this too:
Power to the gauge, then the gauge signal wire grounds through the sender resistor and to the grounded portion of the sender assembly. And the sender assembly needs a good ground to the frame. grounding the pump through the sender unit signal wire as you describe means you are grounding through the variable resistor of the sending unit and possibly through the gauges. neither is meant to ground a load like a fuel pump. Ground your pump to the metal portion of the sender assembly and use a heavy ground wire from sender assembly to the frame - the walbro pump will draw more amps than TBI did |
10-22-2024, 12:37 AM | #6 | |
Senior Member
Join Date: Dec 1999
Location: Southern California
Posts: 2,859
|
Re: 1973 k10 intellitronix fuel gauge issue
Quote:
__________________
Richard 1972 K10 Custom Deluxe SWB Fleetside My build https://67-72chevytrucks.com/vboard/...d.php?t=800746 |
|
10-22-2024, 12:34 PM | #7 |
Senior Member
Join Date: Oct 2013
Location: Santa Paula, CA
Posts: 622
|
Re: 1973 k10 intellitronix fuel gauge issue
It is a stock sending unit from a 87 tbi truck. I reconnected everything and changed the ground wire from the gauges. It seems to be working now. But my voltmeter doesn't work at all. It hasn't worked prior to the fuel gauge issue either. It's just all the way to the left.
__________________
1972 C/10 LWB - Mine 1964 C/10 LWB - My Dad's Instagram: Mike_The_Grad |
10-22-2024, 01:43 PM | #8 |
Registered User
Join Date: Mar 2022
Location: Surrey BC
Posts: 894
|
Re: 1973 k10 intellitronix fuel gauge issue
check to see if the volt meter has power and ground and if you get a voltage reading from those two wires with a multimeter
|
10-22-2024, 03:01 PM | #9 |
Senior Member
Join Date: Oct 2013
Location: Santa Paula, CA
Posts: 622
|
Re: 1973 k10 intellitronix fuel gauge issue
I guess there's a potentiometer adjustment on the back of the gauges. I haven't gotten around to it yet because I had to go to work. I'll check back in when I have an update.
__________________
1972 C/10 LWB - Mine 1964 C/10 LWB - My Dad's Instagram: Mike_The_Grad |
10-22-2024, 06:02 PM | #10 |
Senior Member
Join Date: Oct 2013
Location: Santa Paula, CA
Posts: 622
|
Re: 1973 k10 intellitronix fuel gauge issue
So am I supposed to ground the fuel pump to the frame? I'm confused. I only have 3 wires total for my fuel sending unit assembly. 1 black with an eyelet attached. And a 2 wire weatherpack terminal connector. 1 wire is grey and the other is purple.
__________________
1972 C/10 LWB - Mine 1964 C/10 LWB - My Dad's Instagram: Mike_The_Grad |
10-22-2024, 06:56 PM | #11 |
Registered User
Join Date: Mar 2022
Location: Surrey BC
Posts: 894
|
Re: 1973 k10 intellitronix fuel gauge issue
The connectors / colors on a '87 TBI fuel sender and an autowire classic wiring kit may not match up perfectly.
Can't tell if that is another connector on inside of the sender unit and what wires go where. What you need: two wires to the assembly, one ground from the assembly One wire from fuel gauge goes to sender unit and connects to the variable resistor on float switch - this circuit grounds to the sender assembly One wire from fuel pump relay to the sender assembly and connecting to the red wire from fuel pump. The fuel pump ground needs to go to the metal parts of the sender assembly, there may be a terminal for it to connect to or you need to make something. The ground wire from the top of the sender assembly needs to go to the frame, I'd run a heavier wire, solder the connectors and put some conductive grease on the connections at both ends of the ground wire. |
10-22-2024, 07:47 PM | #12 |
Senior Member
Join Date: Oct 2013
Location: Santa Paula, CA
Posts: 622
|
Re: 1973 k10 intellitronix fuel gauge issue
The American autowire kit has just 1 wire for the sending unit sensor reading. It's a tan colored wire labeled gas gauge. I have that wire connected to the negative of fuel pump and yo the signal wire of the intellitronix gauges. I just downloaded the instructions for dakota digital Grafix gauges because my friend just ordered them for his 67 c10. Yes they are different manufacturers and different eras. But I the dakota digital gauge instructions it specifically states:
For fuel level sensors that are attached to an electric fuel pump, or if you have an electric fuel pump in the tank, make sure that the fuel pump is externally grounded to the vehicle chassis. Attempting to ground the fuel pump to the Dakota Digital Control Box will result in erratic operation and damage to the Control Box. Sounds like it would be the same for any type of aftermarket digital gauges. If this is the case, where the heck do I pick up the fuel sensor level reading from??? I've only got 3 wires to choose from. 2 for fuel pump positive. And negative. And the other black wire with eyelet for grounding to the frame.
__________________
1972 C/10 LWB - Mine 1964 C/10 LWB - My Dad's Instagram: Mike_The_Grad |
10-22-2024, 07:49 PM | #13 |
Senior Member
Join Date: Oct 2013
Location: Santa Paula, CA
Posts: 622
|
Re: 1973 k10 intellitronix fuel gauge issue
Anyone have the fuel system wiring diagram from 1987 r10 tbi? Including fuel pump, gauge, ground circuits.
__________________
1972 C/10 LWB - Mine 1964 C/10 LWB - My Dad's Instagram: Mike_The_Grad |
10-22-2024, 10:50 PM | #14 |
Registered User
Join Date: Mar 2022
Location: Surrey BC
Posts: 894
|
Re: 1973 k10 intellitronix fuel gauge issue
I'll repeat
1 wire to fuel sender from gauge. 1 wire from power to pump ground the pump to the sender assembly ground the sender assembly to the truck --------------- you don't add any power to the sender, it provides a variable ground the gauge reads as fuel level. if you connect the gas gauge to the ground of the fuel pump the gas gauge will see 12V, it won't work, it might get fried. If you are also grounding the fuel pump through the sender resistor I think you risk sparking at the resistor inside the tank. The fuel gauge sends a very low voltage to the sender, not a full 12v |
10-25-2024, 08:12 PM | #15 | |
BMW & ASE Master Certified
Join Date: Feb 2004
Location: Houston, Texas
Posts: 1,266
|
Re: 1973 k10 intellitronix fuel gauge issue
Quote:
if a volt meter gauge does not work, it should only be 2 wires, power and ground. trouble shoot what your missing
__________________
1987 Silverado - L83 5.3 w/ 6L80e ,A/C,P/W,P/L,TILT, HID projectors, Wilwood C-10 Pro Spindles w/ 2018 silverado front brakes & C-5 Corvette Rear Disc Brakes 1999 BMW 528i - 5.7 LS1 w/ 4l60e, Ford 8.8 IRS w31 spline posi & FX-r projector retrofit New project: 2006 BMW x5 6cyl AWD to L83 6l80e 4wd to 2WD / RWD A poor man buy's it twice finally got my domain name back, 87chevy.com.... site rework in progress |
|
10-25-2024, 08:15 PM | #16 | |
BMW & ASE Master Certified
Join Date: Feb 2004
Location: Houston, Texas
Posts: 1,266
|
Re: 1973 k10 intellitronix fuel gauge issue
Quote:
sounds wrong. if wired like you are saying, it will never work. its going strait to ground and may be getting current that can damage gauge. if wire is marked gas gauge, it gets connected to only fuel sending unit wire. that simple sounds like a few wires not wired correctly. this can damage the gauges or sending units. double check wires with volt meter
__________________
1987 Silverado - L83 5.3 w/ 6L80e ,A/C,P/W,P/L,TILT, HID projectors, Wilwood C-10 Pro Spindles w/ 2018 silverado front brakes & C-5 Corvette Rear Disc Brakes 1999 BMW 528i - 5.7 LS1 w/ 4l60e, Ford 8.8 IRS w31 spline posi & FX-r projector retrofit New project: 2006 BMW x5 6cyl AWD to L83 6l80e 4wd to 2WD / RWD A poor man buy's it twice finally got my domain name back, 87chevy.com.... site rework in progress |
|
Bookmarks |
|
|