I’ve got a 1984 C10 and over the weekend my heater blower stopped working. I’ve been chasing wires a trying to see what happened and I discovered that the fuse for the blower is grounded. It didn’t pop or anything, but when I hook up my test light to it, as in the alligator clip side to a positive lead and the probe end on the fuse, it’s grounded. Is that correct? Doesn’t seem right.

If not, anyone have any idea why or how that happened and what I can do to fix it? Let me know if any further information is needed. Thanks in advance!

Last edited by rhamer88; 10-23-2024 at 12:03 AM.
rhamer88 is offline   Reply With Quote
Old 10-23-2024, 11:59 AM   #2
HO455
Post Whore
 
HO455's Avatar
 
Join Date: Feb 2016
Location: Portland Oregon
Posts: 11,276
Re: Blower motor issue

If you have the alligator clip hooked to a 12+ source and the probe end to the fuse and the heater switch is in the fan run position the test light should light as the probe is finding ground through the fan motor.

I'm not familiar with the early 80's C10 heater circuits but I am familiar with the late 80's and early 90's S10 circuits. I can't imagine they are very different.

I would start by disconnecting the blower and with the test lights alligator clip on the battery's negative post put the probe in the rubber connector that was connected to the blower. If things are working correctly you should be able to see differences in the test light as you cycle through the different settings on the blower control. If you get no light and your positive the fuse is good carefully inspect the connector as they can break inside the rubber boot.

If that appears to be good move the probe to the purple wire on the resistor mounted on the heater box and test again.

If still no light move the probe to the tan wire on the resistor. Here you should have the light on with the fan speed in low.

If still no light ad you know the fuse is good then you will need to pull the heater controls. My S10 knowledge probably won't help you as the switches are different switches.

Over the years that I've owned S10's I've had numerous blower switches fail, 2 of connectors at the blower motor fail and one resistor fail. If you inspect the blower control you should be able to visually see if it has overheated and failed.

I hope this helps.
__________________
Thanks to Bob and Jeanie and everyone else at Superior Performance for all their great help.
RIP Bob Parks.
1967 Burban (the WMB),1988 S10 Blazer (the Stink10 II),1969 GTO (the Goat), 1970 Javelin, 1952 F2 Ford OHC six 4X4, 29 Model A, 72 Firebird (the DBP Bird). 85 Alfa Romeo
If it breaks I didn't want it in the first place
The WMB repair thread http://67-72chevytrucks.com/vboard/s...d.php?t=698377
HO455 is offline   Reply With Quote
Old 10-27-2024, 02:14 PM   #3
Axle
Registered User
 
Axle's Avatar
 
Join Date: Jul 2011
Location: SW Ontario
Posts: 1,208
Re: Blower motor issue

1st place I would look is the blower resistor. Comes out with 2 screws. Normally you just lose a speed but it can fully open as well.
Also look inside the blower resistor connector for melting.

If an AC truck, theres a relay mounted to the evaporator box that feeds power to the blower resistor. But start with the resistor.
Axle is offline   Reply With Quote
Old 10-28-2024, 01:50 PM   #4
truckin 79
Registered User
 
Join Date: Jun 2014
Location: CO
Posts: 745
Re: Blower motor issue

Do you have AC in your truck or just the heat controls?
__________________
79 Chevy 2wd BIG10 350 TH400
truckin 79 is offline   Reply With Quote
Old 10-29-2024, 12:46 AM   #5
Pontiac1976
Registered User
 
Pontiac1976's Avatar
 
Join Date: Oct 2015
Location: Ottawa, Ontario, Canada
Posts: 764
Re: Blower motor issue

I would check the resistor to check the Plug as none A/C is two wire plug and A/C plug 4 to 5 -6 rust some time there just to rusty bad connection or may strict out spring crack at the pin. on the fire wall passenger side
__________________
1977 REG cab Long Bed with a 1984 Front Clip, 82 305 .60 over 9.0.1 flat top pistons, 4bbl, TH350, w/84 SS-intake & cam , w/ 1977 big block rad, 1975 gear box, 1984 master w/ metric fittings top & SAE fitting @ portion block, 1975 3.42 gear open diff. Duel 77-87 Factory air cleaner, duel inlet from rad support . Down sized 9' to new 8' Steel flat bed
Was a 77 454 w/308 gear. Taken out 550 lbs. up front with motor clip change.
Pontiac1976 is offline   Reply With Quote
Reply

Bookmarks


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -4. The time now is 03:24 PM.


Powered by vBulletin® Version 3.8.11
Copyright ©2000 - 2024, vBulletin Solutions Inc.
Copyright 1997-2022 67-72chevytrucks.com