electric fan blow air or suck
do the fan suppose to blow air through radiator or suck air got the dual fans off of a nissiam altima and trying to make sure hooked up right, mine are sucking air through radiator
__________________
1997 pontiac grand prix gt (daily driver) for now; 2004 dodge ram quad cab (wife's truck) 4.7; 2000 pontiac booneville (wife daily driver) 1972 chevy cheyenne 350 bored 40 over 700r trans 373 gears ( posi) soon to be daily driver; 2002 gsxr750 sold |
04-19-2007, 05:50 PM | #2 |
Registered User
Join Date: Oct 2005
Location: Sacramento, CA
Posts: 1,970
|
Re: electric fan blow air or suck
Ideally they should pull air from the front of the truck towards the back. Fans mounted engine side of the radiator.
__________________
72 Cheyenne SWB Fleet Nut & bolt frame off in progress...99.9999% - supercharged 383 - 4 wheel discs - relocated fuel tank - My Build Thread |
04-20-2007, 08:43 AM | #3 |
Questionable
Join Date: Mar 2005
Location: Atlanta
Posts: 13,373
|
Re: electric fan blow air or suck
And stock fans vary from vehicle to vehicle - some pull, some push.
Sometimes you can simply reverse the flow of the air by reversing the + and - wires (reverse polarity). It all depends on whether the fan will operate that way - most fans you buy at Summit and Jegs are reversible.
__________________
If I've got anything up for grabs, it'll be here: 7-hole gauge cluster for a 67-72 p/u FREE (link) I can't check the forum daily. If I don't reply to you within 24 hours, drop me a PM! I'm (hopefully) still alive and will reply faster to a PM. |
04-20-2007, 09:52 AM | #4 |
Parts and more parts
Join Date: Nov 2003
Location: Lebo, Kansas (middle of nowhere
Posts: 6,821
|
Re: electric fan blow air or suck
If you go to ANY fan supplier's site and look there are both kinds. The most effieicent are the ones that PULL air through the radiator. Pusher fans are usually used as a supplemental cooling fan for vehicles that tend to overheat. I have dual fans on all of my vehicles and they are all pull type fans and are mounted behind the radiator in the engine compartment.
If you are blending a fan from another vehicle to a radiator that is stock and possibly an older style copper unit, then there may be a chance that you do not cool as well as you would like to. The majority of later model cars are using aluminum finned radiators to get the extra heat transfer that is available with that material. |
04-20-2007, 10:08 AM | #5 |
Registered User
Join Date: Feb 2006
Location: nashville
Posts: 217
|
Re: electric fan blow air or suck
well mine are sucking and I have a low and high speed on both fans so I think the will pull pretty good I think I can run both on low when drivin, and use high with the ac on, when I get it hooked back up, will test later on today
__________________
1997 pontiac grand prix gt (daily driver) for now; 2004 dodge ram quad cab (wife's truck) 4.7; 2000 pontiac booneville (wife daily driver) 1972 chevy cheyenne 350 bored 40 over 700r trans 373 gears ( posi) soon to be daily driver; 2002 gsxr750 sold |
04-20-2007, 07:11 PM | #6 |
Registered User
Join Date: Dec 2006
Location: Rhode Island
Posts: 602
|
Re: electric fan blow air or suck
Suggest mounting on the outside [forward] of the radiator and wire them so they're "pushing" the air into the radiator toward the engine (front to back).
On the average they're about 10% or more, more efficient if set up this way.
__________________
69 C-10 SWB Fleetside 454/TH400 (For Sale) http://67-72chevytrucks.com/vboard/c...ct=1299&cat=12 70 El Camino 454 TH700 29 Model A 4-DR Sedan Deluxe Last edited by mnunn454; 04-20-2007 at 07:11 PM. |
04-20-2007, 08:16 PM | #7 |
Registered User
Join Date: Apr 2000
Location: Bonne Terre, Mo
Posts: 3,005
|
Re: electric fan blow air or suck
If you pushed the air into the rad would you still use a shroud behind the rad? I am not doing this but interested in this thread.
__________________
'69 Chevy Long Fleet & '71 GMC Short Step & Project "ODD BALL" "You can wash a pig, soak it in most expensive perfume. In the end it is still just a pig." ODD BALL build thread http://67-72chevytrucks.com/vboard/s...d.php?t=478629" |
04-20-2007, 09:52 PM | #8 |
Registered User
Join Date: Feb 2006
Location: nashville
Posts: 217
|
Re: electric fan blow air or suck
Fans worked great could feel them pulling the cool air in while it was idling in the yard, drove about 30 miles temp hand never made it half way. Didn't even have to turn on high, also installed headlight relay now I have to gptry them out tomorrow
__________________
1997 pontiac grand prix gt (daily driver) for now; 2004 dodge ram quad cab (wife's truck) 4.7; 2000 pontiac booneville (wife daily driver) 1972 chevy cheyenne 350 bored 40 over 700r trans 373 gears ( posi) soon to be daily driver; 2002 gsxr750 sold |
04-20-2007, 11:15 PM | #9 |
Cereal Killer
Join Date: Jan 2006
Location: Montgomery, Alabama
Posts: 639
|
Re: electric fan blow air or suck
If your trying to use a pusher fan a good portion of the blown air is deflected by the tubes and fins on the rad. My radiator guy always suggests a puller fan.
__________________
If I dont do it....somebody else will. |
04-21-2007, 02:46 AM | #10 |
Registered User
Join Date: Aug 2006
Location: Bakersfield,CA
Posts: 7,893
|
Re: electric fan blow air or suck
nice to hear that your fans are working nicely
puller fans are better since you have the air being pulled through the rad and pushed over the engine, if needed for extra cooling on hot days or hauling a trailer or whatnot you can add a second fan centered on the front of the rad to flip on when/if needed to push extra air over the fins
__________________
-steven Alte Seele S.S. "Allison" '72 C/10 LWB 350SB/TH350 - DD PITBULL IS NOT A CRIME |
04-21-2007, 02:47 AM | #11 |
Registered User
Join Date: Aug 2006
Location: Bakersfield,CA
Posts: 7,893
|
Re: electric fan blow air or suck
what year altima did you pull them out of? v6 or 4banger?
__________________
-steven Alte Seele S.S. "Allison" '72 C/10 LWB 350SB/TH350 - DD PITBULL IS NOT A CRIME |
04-21-2007, 11:28 AM | #12 |
Parts and more parts
Join Date: Nov 2003
Location: Lebo, Kansas (middle of nowhere
Posts: 6,821
|
Re: electric fan blow air or suck
Everyone has an opinion and here is mine. I got it from the discussions that I had with first the "Flexilite" people and second the people from "Be-Cool". You meet some really great people on a Hotrod Power Tour. The pusher fans provide two downfalls--1st) they restrict air flow by being on the front of the radiator. 2nd) they are somewhat inefficient on the fact that in most cases they are up against the radiator and they push air in only the small area that they cover and a lot of that is diffused against the fins and dissapated on the outside of the radiaotr rather than going through it.
The puller fans if mounted right will move more air, give a better flow through the core fins, and provide a better movement of air in the engine compartment. Now comes the decision on what fan to get. There are a lot of them out there on the market and some move some great amounts of air and some are just there to take your money. If you are driving on the highway, then in most cases any fan will do, but if you are going to load up the truck and work in a hot city, then a better grade of fan is needed. I finally settled on the dual 11" fans from SPAL because each fan is rated to move around 2800 CFM of air against a dynamic load. (Dynamic is something such as an engine compartment that has other thnigs happening rather than just an open space). A lot of fans ar tested in a "Static" conditon which is to measure the air flow across from point 'A' to point 'B' which has no backpressure in it. The sales people will tell you that their fan is limited to certain levels of Horsepower With or without A/C on. SPAL dosen't do that. I am running my fans in two different trucks and I can run on a really hot day and have no problems with them. They sound like gas turbine engines up front, but it works well. My setups are designed to run one fan at slow speed, then speed up as the temp goes up, and finally the second fan starts if it is really hot or the A/C is on. I have not gotten to the second fan point yet. I recommend some phone calls to Be-Cool and Flexilite and then do comparisons before doing a lot of work and then just bolting something on. I have seen a lot of really nice Streetrods sitting on the side of the road with water boiling out of them. Imagine putting $5000 in a motor and putting a $19.95 fan on the radiator. NOT ME. Last edited by piecesparts; 04-21-2007 at 11:31 AM. |
04-21-2007, 06:20 PM | #13 |
Registered User
Join Date: Feb 2006
Location: nashville
Posts: 217
|
Re: electric fan blow air or suck
I think that they off a maxium instead about a 90-94 the box style the fans are in a one piece deal with four wires going to each fan a green, blue black and yellow, yellow and black are ground blue and green are hot. blue or green hooked up make it run on low both have to have hot to them to make it run on high, so I put two switches under my dash on for low, other for high
__________________
1997 pontiac grand prix gt (daily driver) for now; 2004 dodge ram quad cab (wife's truck) 4.7; 2000 pontiac booneville (wife daily driver) 1972 chevy cheyenne 350 bored 40 over 700r trans 373 gears ( posi) soon to be daily driver; 2002 gsxr750 sold |
04-21-2007, 08:18 PM | #14 |
Registered User
Join Date: Jan 2006
Location: Morro Bay C.A
Posts: 179
|
Re: electric fan blow air or suck
if you have a pusher and its on when your driving down the road it seems like to me that it would counteract the air blowing in from the grille... i have electric fan set to pull... it just makes sense that way because it pulls the cool air from outside and not the warm air from your engine...
__________________
'69 C10 SWB 350 edelbrock int/carb .420 .442 cam 700r4 70 lwb c10 work truck 250 I6 with two inch lift springs and a two inch bodylift and 33/12.5s |
04-21-2007, 08:34 PM | #15 | |
Parts and more parts
Join Date: Nov 2003
Location: Lebo, Kansas (middle of nowhere
Posts: 6,821
|
Re: electric fan blow air or suck
Quote:
The pusher fan is usually less effective, because of where it mounts and the way it limits a full flow of air into the radiator core. |
|