#1 |
USMC
Join Date: May 2007
Location: SLc,UT
Posts: 300
|
Re: Welders!
.023-.025 wire with 25%CO2/75% argon gas works out well on body panels. Straight CO2 is cheaper and will work but it will run a little hotter.
I got a couple of 1lb rolls of Hobart .024 wire as a sample and really like it. It might even be enough to finish this job out and I wont have to go and pay for more. A .023 tip should work with .025 wire also. I am running the 24 with them and it works fine. I don't think an extra thou or 2 will jam it up.
__________________
Semper Fi |
![]() |
![]() |
![]() |