The 1947 - Present Chevrolet & GMC Truck Message Board Network







Register or Log In To remove these advertisements.

Go Back   The 1947 - Present Chevrolet & GMC Truck Message Board Network > 47 - Current classic GM Trucks > The 1947 - 1959 Chevrolet & GMC Pickups Message Board

Web 67-72chevytrucks.com


Reply
 
Thread Tools Display Modes
Old 11-06-2013, 10:24 PM   #1
Donaldo
Registered User
 
Join Date: Sep 2013
Location: Morro Bay, California
Posts: 447
'51 3100 Cowl Vent Drain Tube

I am keeping the cowl vent operational, just wondering what others here have done with the drain pipe, I really don't want it dripping onto the sbc distributor...

thanks, Don
Donaldo is offline   Reply With Quote
Old 11-06-2013, 11:17 PM   #2
FiftyTwo
Registered User
 
FiftyTwo's Avatar
 
Join Date: Mar 2009
Location: Apple Valley, MN
Posts: 109
Re: '51 3100 Cowl Vent Drain Tube

I smoothed my firewall and ran a small drain tube from the cowl vent down the inside of my truck and routed it outside down where the steering column goes through the firewall. Nothing shows under the hood and you don't see it inside because it's behind the carpet.
FiftyTwo is offline   Reply With Quote
Old 11-06-2013, 11:50 PM   #3
gale
Registered User
 
Join Date: Jun 2013
Location: Houston Texas
Posts: 310
Re: '51 3100 Cowl Vent Drain Tube

I plan to smooth the firewall on my '54. Do you have any pictures? I'll probably use 16 ga. to reduce warping. Good idea on the tube inside.
__________________
Gale Gorman
'54 3100
'67 C20 stepside
gale is offline   Reply With Quote
Old 11-07-2013, 09:58 AM   #4
nvrdone
Registered User
 
Join Date: Dec 2011
Location: Moxee WA
Posts: 1,427
Re: '51 3100 Cowl Vent Drain Tube

I ran a longer hose down the curve of the firewall so the water doesn't drip on the dist. But my truck NEVER gets wet in Seattle !!
nvrdone is offline   Reply With Quote
Old 11-07-2013, 11:56 AM   #5
youngrodder
Registered User
 
youngrodder's Avatar
 
Join Date: Mar 2007
Location: Scotts, Michigan
Posts: 3,758
Re: '51 3100 Cowl Vent Drain Tube

I did the same as fiftytwo, but I also T'd the drain from my vintage air unit into the same hose as thje cowl so they both exit out of the same spot.

Marc
__________________
…………...........__________
.................. ((__|__||___\____
..;.;;.:;:;.,;..;((_(O))____ (_(O))

1948 Chevy Truck - Finished SOLD!!

1953 Chevy Suburban "Family Truckster" Completed: Spring of 2021
http://67-72chevytrucks.com/vboard/s...d.php?t=605484

1994 4x4 Blazer - "Field Find"
https://67-72chevytrucks.com/vboard/...ferrerid=30857
youngrodder is offline   Reply With Quote
Old 11-07-2013, 12:23 PM   #6
NEWFISHER
Registered User
 
NEWFISHER's Avatar
 
Join Date: Sep 2012
Location: Oregon
Posts: 3,303
Re: '51 3100 Cowl Vent Drain Tube

I used a heater hose male/male connector and another foot of heater hose to extend it back behind the engine.
NEWFISHER is offline   Reply With Quote
Old 11-07-2013, 10:22 PM   #7
mechanixman
Registered User
 
mechanixman's Avatar
 
Join Date: Sep 2012
Location: Mt. Prospect, ILL
Posts: 820
Re: '51 3100 Cowl Vent Drain Tube

I haven't finished it yet, but I'm putting in a polished copper hose to run from the original drain connector, and running it down the firewall to the bottom of the cab.
__________________
-Nick

Projects:
1952 Chevy 1 ton = The Build page
mechanixman is offline   Reply With Quote
Old 11-08-2013, 12:03 AM   #8
Donaldo
Registered User
 
Join Date: Sep 2013
Location: Morro Bay, California
Posts: 447
Re: '51 3100 Cowl Vent Drain Tube

Quote:
Originally Posted by youngrodder View Post
I did the same as fiftytwo, but I also T'd the drain from my vintage air unit into the same hose as thje cowl so they both exit out of the same spot.

Marc
Hi Marc, since you mentioned the vintager air unit - I am leaning in that direction also - what do you think if it and would you make any changes ?

Don
Donaldo is offline   Reply With Quote
Old 11-08-2013, 11:12 AM   #9
youngrodder
Registered User
 
youngrodder's Avatar
 
Join Date: Mar 2007
Location: Scotts, Michigan
Posts: 3,758
Re: '51 3100 Cowl Vent Drain Tube

Quote:
Originally Posted by Donaldo View Post
Hi Marc, since you mentioned the vintager air unit - I am leaning in that direction also - what do you think if it and would you make any changes ?

Don
Don-

Overall I like it. If I was to do it again I would not buy it as a kit. It came with hard lines that you connect to the unit. Since mine connects to a aftermarket bulk head in the firewall (last pic), I could not use the supplied pre-bent lines as they were designed to hook up to the supplied bulk head cover. I had to remake them out of rubber hose (2nd pic). It was a tight fit (1st pic). I also shortened up by glove box liner by 4" so that I can have a functional glove box.

Here are some pics.



Marc
Attached Images
   
__________________
…………...........__________
.................. ((__|__||___\____
..;.;;.:;:;.,;..;((_(O))____ (_(O))

1948 Chevy Truck - Finished SOLD!!

1953 Chevy Suburban "Family Truckster" Completed: Spring of 2021
http://67-72chevytrucks.com/vboard/s...d.php?t=605484

1994 4x4 Blazer - "Field Find"
https://67-72chevytrucks.com/vboard/...ferrerid=30857
youngrodder is offline   Reply With Quote
Old 11-08-2013, 11:56 AM   #10
gale
Registered User
 
Join Date: Jun 2013
Location: Houston Texas
Posts: 310
Re: '51 3100 Cowl Vent Drain Tube

Good looking work and truck. I like the color also. Do you have a picture or two showing more of you firewall smoothing? That's coming up right away for me on my '54 and I'm trying to decide how far I want to take it.
__________________
Gale Gorman
'54 3100
'67 C20 stepside
gale is offline   Reply With Quote
Old 11-08-2013, 01:08 PM   #11
youngrodder
Registered User
 
youngrodder's Avatar
 
Join Date: Mar 2007
Location: Scotts, Michigan
Posts: 3,758
Re: '51 3100 Cowl Vent Drain Tube

Quote:
Originally Posted by gale View Post
Good looking work and truck. I like the color also. Do you have a picture or two showing more of you firewall smoothing? That's coming up right away for me on my '54 and I'm trying to decide how far I want to take it.
Thanks
PM sent. I dont what to highjack this thread..

Marc
__________________
…………...........__________
.................. ((__|__||___\____
..;.;;.:;:;.,;..;((_(O))____ (_(O))

1948 Chevy Truck - Finished SOLD!!

1953 Chevy Suburban "Family Truckster" Completed: Spring of 2021
http://67-72chevytrucks.com/vboard/s...d.php?t=605484

1994 4x4 Blazer - "Field Find"
https://67-72chevytrucks.com/vboard/...ferrerid=30857
youngrodder is offline   Reply With Quote
Old 11-08-2013, 02:15 PM   #12
Donaldo
Registered User
 
Join Date: Sep 2013
Location: Morro Bay, California
Posts: 447
Re: '51 3100 Cowl Vent Drain Tube

""Since mine connects to a aftermarket bulk head in the firewall (last pic),""

I do like the look of the firewall connections compared to the round hole filler contraption they offer - will they adapt to that style or is it up to the owner ? Does the VA unit you used bolt up using the original 2 mounting holes or ??
Don
Donaldo is offline   Reply With Quote
Old 11-08-2013, 02:16 PM   #13
Donaldo
Registered User
 
Join Date: Sep 2013
Location: Morro Bay, California
Posts: 447
Re: '51 3100 Cowl Vent Drain Tube

Quote:
Originally Posted by youngrodder View Post
Thanks
PM sent. I dont what to highjack this thread..

Marc
I believe there is a smooth firewall thread going on - or add to this one.

Don
Donaldo is offline   Reply With Quote
Old 11-08-2013, 02:32 PM   #14
youngrodder
Registered User
 
youngrodder's Avatar
 
Join Date: Mar 2007
Location: Scotts, Michigan
Posts: 3,758
Re: '51 3100 Cowl Vent Drain Tube

Quote:
Originally Posted by Donaldo View Post
""Since mine connects to a aftermarket bulk head in the firewall (last pic),""

I do like the look of the firewall connections compared to the round hole filler contraption they offer - will they adapt to that style or is it up to the owner ? Does the VA unit you used bolt up using the original 2 mounting holes or ??
Don
I was going to mention this but using a bulkhead like mine increases your cost a couple hundred dollars in just fittings alone (not including the cost of the bulkhead). Each fitting that screws into the bulk head is between $10-20 ea. depending on the size and angle. Then x 2 (one for each side of the firewall). Since my firewall was not stock, I mounted mine differently. I tucked mine up high as I didn't want it to be seen hanging down low under the dash. You can pretty much mount in a way that works best for your application.

It is really up to the owner to configure as the relationship of the bulkhead compared to where the unit is mounted makes it somewhat custom. You need to figure out how your hoses will run before getting the ends crimped on.

Here are a couple more pics that my friend Wayne sent me when I was fabricating my set up. This was in a 48 Suburban.


Marc
Attached Images
   
__________________
…………...........__________
.................. ((__|__||___\____
..;.;;.:;:;.,;..;((_(O))____ (_(O))

1948 Chevy Truck - Finished SOLD!!

1953 Chevy Suburban "Family Truckster" Completed: Spring of 2021
http://67-72chevytrucks.com/vboard/s...d.php?t=605484

1994 4x4 Blazer - "Field Find"
https://67-72chevytrucks.com/vboard/...ferrerid=30857
youngrodder is offline   Reply With Quote
Reply

Bookmarks


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -4. The time now is 11:32 PM.


Powered by vBulletin® Version 3.8.11
Copyright ©2000 - 2024, vBulletin Solutions Inc.
Copyright 1997-2022 67-72chevytrucks.com