Register or Log In To remove these advertisements. |
|
|
|
Thread Tools | Display Modes |
01-13-2004, 06:04 PM | #1 |
Registered User
Join Date: Nov 2000
Location: Huntsville Ontario Canada
Posts: 4,051
|
A/C help needed. Re. 87 Burb
We have a 87 burb the and the A/C has stopped working. When we checked for power at the compressor there was none. Why would there be no power ? Is there a swithch that could have gone bad at the inside controll ? We checked the fuse it's good any other Ideas ?
Thanks
__________________
1968 Suburban numbers matching all original truck now equipped with 6.0/4L80 on Accuair http://67-72chevytrucks.com/vboard/s...d.php?t=625017 1967 C/20 6.0/4L80 Roofing Truck 1990 V2500 Suburban "Plow Truck" 2005 TAHOE DD |
01-13-2004, 07:22 PM | #2 |
Insert Witty Text Here
Join Date: Oct 2002
Location: San Antonio, TX
Posts: 3,415
|
If there is no freon (or low on freon), there is a switch that kills the power to the system. I don't know the details, but it is on one of the lines on the box on the firewall. It will be the lump with the wires going to it.
Slonaker |
01-13-2004, 08:22 PM | #3 |
STILL PLAYS WITH TRUX
Join Date: Nov 2002
Location: Melbourne, Fla.
Posts: 2,764
|
Slonaker is sorta right.
There's a pressure sw. mounted on the receiver drier take off the connector and jumper it then remove the connector on the compressor and hook up a test light to it and put the selector in any A/C position and see if you get pwr @ the compressor. If so then you need to ck. the sys. for leaks & repair them and service it. If not then it could be the sw. or a wireing problem but i'd look at the sw. first. |
01-13-2004, 09:30 PM | #4 |
Registered User
Join Date: Nov 2000
Location: Huntsville Ontario Canada
Posts: 4,051
|
How do i jumper it ? I know that there is no freon. In the system. So that's my problem. But I want to make sure that when the switch is in the on postion the comperssor actually locks up and starts pumping.
Thanks
__________________
1968 Suburban numbers matching all original truck now equipped with 6.0/4L80 on Accuair http://67-72chevytrucks.com/vboard/s...d.php?t=625017 1967 C/20 6.0/4L80 Roofing Truck 1990 V2500 Suburban "Plow Truck" 2005 TAHOE DD |
01-13-2004, 09:31 PM | #5 |
Registered User
Join Date: Nov 2000
Location: Huntsville Ontario Canada
Posts: 4,051
|
before I have the system Charged
__________________
1968 Suburban numbers matching all original truck now equipped with 6.0/4L80 on Accuair http://67-72chevytrucks.com/vboard/s...d.php?t=625017 1967 C/20 6.0/4L80 Roofing Truck 1990 V2500 Suburban "Plow Truck" 2005 TAHOE DD |
01-13-2004, 09:43 PM | #6 |
STILL PLAYS WITH TRUX
Join Date: Nov 2002
Location: Melbourne, Fla.
Posts: 2,764
|
To jumper the press. sw. just take a piece of wire about 2.5" long strip both ends and insert them into the connector cavity's
I reccomend not runing the eng. when doing this cuz you may cause damage to the compressor. If the sys. is sound you should be able to hear the clutch click when you turn it on place the Ign. key into the Assy position and turn the A/C on & off a few times. If you dont hear anything then the clutch may be bad that's why i said to hook up a test light @ the compressor that way you know there's power or not. |
Bookmarks |
|
|