07-22-2018, 07:54 PM | #1 |
Registered User
Join Date: Feb 2016
Location: SpringCity
Posts: 37
|
Dang gas hand
Ok I had to clean my gas tank out and when I put it back in my gas hand don't want to work the wire on top of the tank when I loosen it the hand goes past full when I tighten it the thing goes empty this is on a 68 C10 any help would be appreciated
|
07-22-2018, 08:14 PM | #2 |
Registered User
Join Date: Jul 2013
Location: LI, NY 11801
Posts: 1,140
|
Re: Dang gas hand
I assume you are referring to the needle on the gas gauge?
__________________
1970 C10 8' Fleetside, L6 250, 3 on the Tree. The most basic of pickup trucks! |
07-22-2018, 08:16 PM | #3 |
Registered User
Join Date: Feb 2016
Location: SpringCity
Posts: 37
|
Re: Dang gas hand
Yes sorry I should have mentioned the needle
|
07-22-2018, 08:27 PM | #4 |
Moderator
Join Date: Jun 2017
Location: Cherryville, NC
Posts: 2,204
|
Re: Dang gas hand
When you put the fuel gauge sender back in the tank, you did make sure the float was on the unit and the float did not have any holes in it?
Also, did you by chance paint the mounting tabs in the cab when you had the tank out? The tank needs to be grounded to the cab...for the gauge system to work correctly. |
07-22-2018, 08:33 PM | #5 |
Registered User
Join Date: Feb 2016
Location: SpringCity
Posts: 37
|
Re: Dang gas hand
The float is fine and the inside was not painted that is why it is so confusing I know about the tab for grounding the thing un grounded the needle goes way past full
|
07-22-2018, 08:41 PM | #6 |
Moderator
Join Date: Jun 2017
Location: Cherryville, NC
Posts: 2,204
|
Re: Dang gas hand
Sounds like the sender unit is bad...grab another known good one and swap em out...keep us up to date on progress.
I didnt mean painting inside the tank...I was referring to painting the cab where the tank mounts...at least one mount area should be a good clean ground for the tank |
07-22-2018, 08:43 PM | #7 |
Registered User
Join Date: Feb 2016
Location: SpringCity
Posts: 37
|
Re: Dang gas hand
Thanks I'll work on it
|
07-22-2018, 10:49 PM | #8 |
Msgt USAF Ret
Join Date: Jan 2005
Location: Kalamazoo, Michigan
Posts: 8,719
|
Re: Dang gas hand
Your sending unit terminal may be grounded to the tank and not reading through the resistor in the sender. Check it with a meter for continuity to the locking tab or the cab itself. If you get an ohms reading it should correspond to the amount of fuel in the tank.
I.E. 25 ohms = 1/4 tank, 50 ohms=1/2 tqnk etc. Most likely the wire that connects to the terminal is grounded to the cab. Pull the sender wire off at the fuse panel terminal marked "fuel" and with it off at the sender terminal, check the wire to a good ground for continuity. You should get infinity, OL on the meter
__________________
VetteVet metallic green 67 stepside 74 corvette convertible 1965 Harley sportster 1995 Harley wide glide Growing old is hell, but it beats the alternative. |
07-23-2018, 06:53 AM | #9 |
Registered User
Join Date: Apr 2011
Location: Fairview Park, Ohio
Posts: 1,031
|
Re: Dang gas hand
You can run a temp wire from the fuse panel to the sender to check.
I second the thought on sender wire grounding out.
__________________
My build page http://67-72chevytrucks.com/vboard/s...d.php?t=764662 My cabinet building site http://www.cbcabinets.com |
Bookmarks |
|
|