Need help with heater problem
Hey guys, well finally got the chance to look at my 72 blower not working. Turns out the blower relay wasn't there, PO did some "creative" wiring on this truck. Anyway got it to work while the relay is on order. Problem I'm having is no matter where I have the controls, all the air blows out of the a/c vents. I'm trying to make sure I have heat and defrosters for the cool weather. The cables seem to be moving, but nothing out of the floor vent or the defrosters regardless of where I move the controls.
Any help or suggestions would be appreciated. Thanks. |
![]() |
![]() |
![]() |
#2 |
Registered User
Join Date: Feb 2002
Location: Vacaville, CA
Posts: 2,745
|
Check the flapper valve in your diverter box, I bet it is broken.
__________________
![]() ![]() 99 Pontiac S/C GTP, SLP Ram Air hood, GMPP Konis & springs 95 Neon ACR, MP PCM, AFX UDP, 3.0 CAI |
![]() |
![]() |
![]() |
#3 |
Senior Member
![]() Join Date: Sep 2002
Location: Hampstead, NC
Posts: 8,193
|
Thanks Neonlarry, can u tell me how I can get to it?
|
![]() |
![]() |
![]() |
#4 |
Registered User
Join Date: Feb 2002
Location: Vacaville, CA
Posts: 2,745
|
This is a pic of diverter box under dash. The flapper valve is in the center it usually breaks along the shaft it pivots on.
__________________
![]() ![]() 99 Pontiac S/C GTP, SLP Ram Air hood, GMPP Konis & springs 95 Neon ACR, MP PCM, AFX UDP, 3.0 CAI |
![]() |
![]() |
![]() |
#5 |
Senior Member
![]() Join Date: Sep 2002
Location: Hampstead, NC
Posts: 8,193
|
Thanks again, I found it and pushed it back so the air is flowing where I need it for now.
Thanks for all your help. |
![]() |
![]() |
![]() |
#6 |
Registered User
Join Date: Feb 2002
Location: Vacaville, CA
Posts: 2,745
|
Some people have been able to repair the broken valve using some metal straps or fiberglass. Sure beats paying for a new one.
__________________
![]() ![]() 99 Pontiac S/C GTP, SLP Ram Air hood, GMPP Konis & springs 95 Neon ACR, MP PCM, AFX UDP, 3.0 CAI |
![]() |
![]() |
![]() |
#7 |
Senior Member
![]() Join Date: Sep 2002
Location: Hampstead, NC
Posts: 8,193
|
I'll have to check it out better. BTW I installed a new blower motor and blow relay but the blower still doesn't work correctly on high. It does work, but at the same speed as the previous setting. Any ideas?
Thanks again. |
![]() |
![]() |
![]() |
#8 |
Registered User
Join Date: May 2004
Location: Canton North Carolina
Posts: 466
|
Your switch may be bad at the high position, it is just a slide switch moving across contact points and they burn up after a time, it could be the next easy check for you.
|
![]() |
![]() |
![]() |
#9 |
Registered User
Join Date: Jun 2002
Location: Knoxville Tenn.
Posts: 3,058
|
When you installed the relay did you make sure the relay was getting a good ground (black wire that hooks to the relay mounting screw). To check your ground run a jumper wire from the relay to a good ground.
__________________
56 Chevy Bel-Air 2dr. HT (purchased new) 71 Chevy Cheyenne SWB PU (502HO) 65 GMC short bed step--work in progress and my gofer |
![]() |
![]() |
![]() |
#10 |
Senior Member
![]() Join Date: Sep 2002
Location: Hampstead, NC
Posts: 8,193
|
thanks guys....I did make sure I was getting power from the switch on high position, but did not attached the ground wire. The end of off it and I was in a bit of a hurry. I'll properly mount and attach the ground and see what happens.
thanks again. |
![]() |
![]() |
![]() |